  After this measure, move the manometer, re-screw the screw-cap, and verify that there are not leaks.  

 

Nominal heat input of appliance can be measured using the gas meter instrument of the premise and a 
chronometer;  you  have  to  measure  the  exact  gas  flow  per  unit  of  time,  which  is  consumed  when  the 
water grill (being the only gas heating appliance on) is working at maximum power. This measurement 
should be compared to the gas consumption data in technical table A. The tolerance of 

±

 5 % is allowed 

for this measure. If you are measuring top deviations, you should carefully check the diameters and the 
quality of the installed nozzles and verify the pressure of the gas network. 
 
 
3.6 

Adaptation to a different gas 

 
If current gas setting of the water grill, which can be verified on labels (either in packaging or in the label 
fixed on the back of it), does not correspond to gas available in place the gas adaptation must be carried 
out. 
The  appliance  should  only  be  adapted  by  a  professionally  qualified  technician.  With  reference  to 
technical data of table 3, replace the main nozzles, the pilot nozzles, adjust correctly the primary air of  
bush and then adjust the by-pass screws on gas tapes to set the right rate at the reduced heat input. 
Spare nozzles are provided with the appliance on its delivery or can be ordered near the seller. 
Make  sure  that  the  diameter  is  printed  on  each  nozzle  in 

1/100

ths  of  a  millimetre.  Only  adapt  the 

appliance  after  you  have  turned  the  gas  off  with  the  on/off  valve  upstream  and  let  the  appliance  cool 
down. 
 
3.6.1  Replacing the main nozzle and adjusting its primary air  
 
For each main burner, consult technical data on table 3, see Fig. 4 and proceed as follows: 
 

  Access to the main burner after removing the cooking grids, the radiant elements, the drawers and , 

in case, overturn the appliance to work easily. 

  Unscrew and change the main nozzle “ I “ with the one for the new gas type. 

  Adjust correctly the distance H of primary air bush “ B “ according to the new gas setting. 

  Fix the air bush by the screw “ V “ 

  Then replace all the components of the water grill in the reverse order. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

B  =  Primary air bush 

H  =  Primary air distance 

=  Main nozzle 

R  =  Main burner 

V  =  Fixing screw 

Z  =  Gas copper pipe Ø 10 mm 

 

I

B

R

V

Z

 

Fig. 4_Main nozzle change 

Summary of Contents for GR150

Page 1: ...EATED WATER GRILL Models GR400 GR200 GR150 GR80 Category II2H3 Installation type A1 0705 i SOTIRIOS D PRODANAS C O PROFESSIONAL ELECTRIC GAS EQUIPMENT FOR RESTAURANTS PATISSERIES SNACK BARS NATIONAL ROAD KILKIS THESSALONIKI P C 61100 GALLIKOS KILKIS CROSSROADS P O BOX 40070 P C 56404 TEL 30 23410 41991 41819 FAX 30 23410 41539 email info north gr Http www north gr ...

Page 2: ...sure and nominal heat input controls 3 6 Adaptation to a different gas 3 6 1 Replacing the main nozzle and adjusting its primary air 3 6 2 Replacing the pilot nozzle and adjusting its primary air 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw 3 7 Interventions repairs and replacements 4 INSTRUCTIONS FOR USING THE WATER GRILL for the user Page 10 4 1 Preliminary warnings be...

Page 3: ... valid for the water grill described in this manual relevant to category II2H3 for Great Britain If the appliance is sold in a different European country with different category pressure and gases reported on the specifications data plate the manual shall be translated into the official language with the references gas connections and local installation regulations of that country Producer is resp...

Page 4: ...dard EN ISO 228 1 2 2 Technical data plates On the back of appliance there is a technical plate Fig 1 and gas setting plate Fig 2 reporting the current gas setting nominal data of grill and a table with gases categories and pressures for all the other EC countries There is also a warning plate expressed in the language of the country of destination Fig 3 A third plate with warning and current sett...

Page 5: ...vacuating the products of combustion to the outside of the room in which the appliance is installed The combustion air and the burned gases evacuation take place in the same room in which the appliance is installed However the appliances must be installed in places appropriate for the removal of fumes according to installation specifications Our grills are considered see technical data table as ap...

Page 6: ...age occurs testing along the whole gas circuit and using leak finder sprays or other non corrosive foams do not use direct flames to look for leaks The burners are manufactured with a way to stand thermal and mechanical stress and are equipped with fixed nozzles This is why it is necessary to change the nozzles every time you change the type of gas Data concerning the appliance setting are to be f...

Page 7: ...ce to technical data of table 3 replace the main nozzles the pilot nozzles adjust correctly the primary air of bush and then adjust the by pass screws on gas tapes to set the right rate at the reduced heat input Spare nozzles are provided with the appliance on its delivery or can be ordered near the seller Make sure that the diameter is printed on each nozzle in 1 100ths of a millimetre Only adapt...

Page 8: ... replace all the components in the reverse order 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw The nozzle of the valve by pass screw has a hole of 1 10 mm Ø and for the gas G30 G31 must be fully screwed down Procced in the same way for each burner For the other gases G20 and G25 the by pass screw must be unscrewed for 1 complete round turning the screw anti clockwise unti...

Page 9: ... are operating property Explosions in the burners Check the pressure of the gas The pilot burner does not alight Ignition plug is faulty out of place or its electrical wire is disconnected Insufficient gas pressure Pilot nozzle is obstructed Gas tap is faulty The pilot burner flame does not keep alight Thermocouple is faulty it is not well licked up and heated by the pilot flame The main burner is...

Page 10: ...water grill only to cook food Do not use it for different purposes because any other use is considered improper and dangerous Control the grill when operating Check the regular lighting of the main burner and verify the stability of the flames passing from the maximum to the minimum setting Blue color of flames is an indication of good combustion Before employing the grill for the first time clean...

Page 11: ...specific oil If such an accurate observance of the contained instructions in this manual are observed NORTH appliances will allow perfect use and performances for a long time The manufacturer cannot be held responsible for any damage caused to property human beings or animals due to misuse of the appliances or non observance of instructions included in this manual 4 4 Technical data table and pres...

Reviews: