background image

 

 
 
3.3 

Positioning 

 
Make  sure  there  is  enough  space available  to  place  the  appliance  and  that  the  surface  it  stands  on  is 
stable and level.  
Make sure the appliance is level on the surface available. If necessary, regulate its height accordingly, 
by adjusting the legs of the appliance.

 

Make sure that the volume of air required for combustion isn't obstructed in any way by objects around or 
under the appliance and no flammable bottle is placed near it. 
It is recommended always keeping a distance of at least 20 cm from the two side walls and rear wall and 
the  appliance  especially  if  the  adjacent  walls  are  not  protected  with  refractory  sheets  or  fire-resistant 
materials made (see Fig. 3B on previous page).  
 
3.4 

Gas connection to the network 

 
Before connecting the appliance to the gas network make sure that:  
 

  The present gas on the place corresponds to that for which the apparatus is predisposed: In If it is not 

does  not  proceed  with  the  connection.  Regulate  the  appliance  for  the  gas  available  following 
instructions under 3.6. 

 

The  fixed  part  of  the  gas  system  is  conform  to  the  prescriptions  established  in  the  Building 
Regulations in force in the Country. In particular, verify that the sections of the gas pipes guarantee a 
supply  that  is  sufficient  for  all  of  the  gas  heated  appliances  installed  in  the  same  premise  avoiding 
excessive pressure drops. 

 

 

The gas bottle (if present) is placed correctly and protected in a dry area; verify that the visible  gas 
pipes can easily be inspected; if pipes have been installed in chases (in floors and walls), make sure 
that this work has been done to a professional standard with reference points that make it possible to 
find the pipeline.

 

 

The flexible hose does not touch hot surfaces, that it isn't put under stress and traction and doesn't 
come into contact with sharp edges or other things that could damage it.

 

  No gas leakage occurs testing along the whole gas circuit and using leak finder sprays or other non-

corrosive foams (do not use direct flames to look for leaks). 

  The burners are manufactured with a way to stand thermal and mechanical stress and are equipped 

with fixed nozzles. This is why it is necessary to change the nozzles every time you change the type 
of gas. 

  Data concerning the appliance setting are to be found on the label on the backside of the appliance. 

  Connect the machine to the network using metal pipes, either rigid or flexible. 

  Verify that the pressure in use is that of exercise for which the appliance has been predisposed. In no 

case  the  inlet  supplying  pressure  must  exceed  the  maximal  pressure  foreseen  by  gas  setting  and 
category according to the Country of destination (see table 4 at last page). 

  Use the right sealing materials for all connections and check them for leaks.  

  It  is  important  for  the  adjacent  walls  to  the  appliance  to  be  protected  against  the  heat.  Interpose 

refractory sheets or place the appliance at least 20 cm of distance from the side or back walls.  

  The connection of the apparatus to the gas network must be effected through a gate valve. This valve 

should be closed when the appliance is not in operation.  

 

 
3.5 

Gas pressure and nominal heat input controls 

 
The  main  inlet  pressure  is  measured,  being  the  appliance  on,  using  a  pressure  gauge  for  liquids  (for 
example a manometer with a minimum resolution of 0,1 mbar). Please proceed as follow: 
 

  Open the frontal panel in way to enter to the ramp of feeding of water grill. 

  Unscrew the screw-cap of pressure point (pressure point is positioned along the gas ramp between 

the external threaded connection and the gas tap). 

  Connect the manometer and measure the inlet pressure (with the appliance in operation). 

  If the value is not between the min. and max. values indicated in the table 4 (reporting pressures for 

every Country, categories and types of gases), the appliance cannot be put into service definitely and 
the gas company must be informed in order to find out the problems of supply pressure. 

Summary of Contents for GR150

Page 1: ...EATED WATER GRILL Models GR400 GR200 GR150 GR80 Category II2H3 Installation type A1 0705 i SOTIRIOS D PRODANAS C O PROFESSIONAL ELECTRIC GAS EQUIPMENT FOR RESTAURANTS PATISSERIES SNACK BARS NATIONAL ROAD KILKIS THESSALONIKI P C 61100 GALLIKOS KILKIS CROSSROADS P O BOX 40070 P C 56404 TEL 30 23410 41991 41819 FAX 30 23410 41539 email info north gr Http www north gr ...

Page 2: ...sure and nominal heat input controls 3 6 Adaptation to a different gas 3 6 1 Replacing the main nozzle and adjusting its primary air 3 6 2 Replacing the pilot nozzle and adjusting its primary air 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw 3 7 Interventions repairs and replacements 4 INSTRUCTIONS FOR USING THE WATER GRILL for the user Page 10 4 1 Preliminary warnings be...

Page 3: ... valid for the water grill described in this manual relevant to category II2H3 for Great Britain If the appliance is sold in a different European country with different category pressure and gases reported on the specifications data plate the manual shall be translated into the official language with the references gas connections and local installation regulations of that country Producer is resp...

Page 4: ...dard EN ISO 228 1 2 2 Technical data plates On the back of appliance there is a technical plate Fig 1 and gas setting plate Fig 2 reporting the current gas setting nominal data of grill and a table with gases categories and pressures for all the other EC countries There is also a warning plate expressed in the language of the country of destination Fig 3 A third plate with warning and current sett...

Page 5: ...vacuating the products of combustion to the outside of the room in which the appliance is installed The combustion air and the burned gases evacuation take place in the same room in which the appliance is installed However the appliances must be installed in places appropriate for the removal of fumes according to installation specifications Our grills are considered see technical data table as ap...

Page 6: ...age occurs testing along the whole gas circuit and using leak finder sprays or other non corrosive foams do not use direct flames to look for leaks The burners are manufactured with a way to stand thermal and mechanical stress and are equipped with fixed nozzles This is why it is necessary to change the nozzles every time you change the type of gas Data concerning the appliance setting are to be f...

Page 7: ...ce to technical data of table 3 replace the main nozzles the pilot nozzles adjust correctly the primary air of bush and then adjust the by pass screws on gas tapes to set the right rate at the reduced heat input Spare nozzles are provided with the appliance on its delivery or can be ordered near the seller Make sure that the diameter is printed on each nozzle in 1 100ths of a millimetre Only adapt...

Page 8: ... replace all the components in the reverse order 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw The nozzle of the valve by pass screw has a hole of 1 10 mm Ø and for the gas G30 G31 must be fully screwed down Procced in the same way for each burner For the other gases G20 and G25 the by pass screw must be unscrewed for 1 complete round turning the screw anti clockwise unti...

Page 9: ... are operating property Explosions in the burners Check the pressure of the gas The pilot burner does not alight Ignition plug is faulty out of place or its electrical wire is disconnected Insufficient gas pressure Pilot nozzle is obstructed Gas tap is faulty The pilot burner flame does not keep alight Thermocouple is faulty it is not well licked up and heated by the pilot flame The main burner is...

Page 10: ...water grill only to cook food Do not use it for different purposes because any other use is considered improper and dangerous Control the grill when operating Check the regular lighting of the main burner and verify the stability of the flames passing from the maximum to the minimum setting Blue color of flames is an indication of good combustion Before employing the grill for the first time clean...

Page 11: ...specific oil If such an accurate observance of the contained instructions in this manual are observed NORTH appliances will allow perfect use and performances for a long time The manufacturer cannot be held responsible for any damage caused to property human beings or animals due to misuse of the appliances or non observance of instructions included in this manual 4 4 Technical data table and pres...