background image

 

 
 
 

 

 
 

 

 
 
 
 
 

 

 

USE AND MAINTENANCE 

INSTRUCTIONS 

(

Version for Great Britain and Ireland

) 

 
 

 

 
 
 
 
 
 

 

 
 
 
 
 

 
 

 
 

Carefully read the manual before  

installing and operating this gas heated water grill 

GAS HEATED WATER GRILL 

 

Models 

         GR400 – GR200 – GR150 - GR80 

 

 

 

  

Category: II2H3+

 

 

Installation type: A

1

 

 
 

0705

 

 

i

 

 

 

 

SOTIRIOS D. PRODANAS & C.O. 

PROFESSIONAL ELECTRIC & GAS EQUIPMENT FOR RESTAURANTS – PATISSERIES – SNACK BARS 

NATIONAL ROAD KILKIS – THESSALONIKI. P.C.:61100 GALLIKOS KILKIS CROSSROADS – P.O. BOX: 40070. P.C 56404 
TEL : + 30 23410 41991, 41819, - FAX: + 30 23410 41539 - email: info

@

north.gr – Http: //www.north.gr 

Summary of Contents for GR150

Page 1: ...EATED WATER GRILL Models GR400 GR200 GR150 GR80 Category II2H3 Installation type A1 0705 i SOTIRIOS D PRODANAS C O PROFESSIONAL ELECTRIC GAS EQUIPMENT FOR RESTAURANTS PATISSERIES SNACK BARS NATIONAL ROAD KILKIS THESSALONIKI P C 61100 GALLIKOS KILKIS CROSSROADS P O BOX 40070 P C 56404 TEL 30 23410 41991 41819 FAX 30 23410 41539 email info north gr Http www north gr ...

Page 2: ...sure and nominal heat input controls 3 6 Adaptation to a different gas 3 6 1 Replacing the main nozzle and adjusting its primary air 3 6 2 Replacing the pilot nozzle and adjusting its primary air 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw 3 7 Interventions repairs and replacements 4 INSTRUCTIONS FOR USING THE WATER GRILL for the user Page 10 4 1 Preliminary warnings be...

Page 3: ... valid for the water grill described in this manual relevant to category II2H3 for Great Britain If the appliance is sold in a different European country with different category pressure and gases reported on the specifications data plate the manual shall be translated into the official language with the references gas connections and local installation regulations of that country Producer is resp...

Page 4: ...dard EN ISO 228 1 2 2 Technical data plates On the back of appliance there is a technical plate Fig 1 and gas setting plate Fig 2 reporting the current gas setting nominal data of grill and a table with gases categories and pressures for all the other EC countries There is also a warning plate expressed in the language of the country of destination Fig 3 A third plate with warning and current sett...

Page 5: ...vacuating the products of combustion to the outside of the room in which the appliance is installed The combustion air and the burned gases evacuation take place in the same room in which the appliance is installed However the appliances must be installed in places appropriate for the removal of fumes according to installation specifications Our grills are considered see technical data table as ap...

Page 6: ...age occurs testing along the whole gas circuit and using leak finder sprays or other non corrosive foams do not use direct flames to look for leaks The burners are manufactured with a way to stand thermal and mechanical stress and are equipped with fixed nozzles This is why it is necessary to change the nozzles every time you change the type of gas Data concerning the appliance setting are to be f...

Page 7: ...ce to technical data of table 3 replace the main nozzles the pilot nozzles adjust correctly the primary air of bush and then adjust the by pass screws on gas tapes to set the right rate at the reduced heat input Spare nozzles are provided with the appliance on its delivery or can be ordered near the seller Make sure that the diameter is printed on each nozzle in 1 100ths of a millimetre Only adapt...

Page 8: ... replace all the components in the reverse order 3 6 3 Adjusting the minimum rate on gas valve through the by pass screw The nozzle of the valve by pass screw has a hole of 1 10 mm Ø and for the gas G30 G31 must be fully screwed down Procced in the same way for each burner For the other gases G20 and G25 the by pass screw must be unscrewed for 1 complete round turning the screw anti clockwise unti...

Page 9: ... are operating property Explosions in the burners Check the pressure of the gas The pilot burner does not alight Ignition plug is faulty out of place or its electrical wire is disconnected Insufficient gas pressure Pilot nozzle is obstructed Gas tap is faulty The pilot burner flame does not keep alight Thermocouple is faulty it is not well licked up and heated by the pilot flame The main burner is...

Page 10: ...water grill only to cook food Do not use it for different purposes because any other use is considered improper and dangerous Control the grill when operating Check the regular lighting of the main burner and verify the stability of the flames passing from the maximum to the minimum setting Blue color of flames is an indication of good combustion Before employing the grill for the first time clean...

Page 11: ...specific oil If such an accurate observance of the contained instructions in this manual are observed NORTH appliances will allow perfect use and performances for a long time The manufacturer cannot be held responsible for any damage caused to property human beings or animals due to misuse of the appliances or non observance of instructions included in this manual 4 4 Technical data table and pres...

Reviews: