North CORFU Installation And Service Instructions Manual Download Page 4

1. GENERAL INFORMATION

 This  technical  manual  includes instructions for  the installation,  operation,  care and

maintenance of electric ovens manufactured by

NORTH

. Please, read carefully and

keep it  for future reference. This manual  should be referred to both by installing or
service technicians and the operators of the equipment.

 After  you  remove  the  packing  make  sure  that  no  damage  was  caused  during

shipping.  If  in  doubt,  we  recommend  that  an  authorized  technician  examine  the
appliance before you proceed with the installation.

 The  appliance  requires  electrical  connection.  Before  proceeding,  make  sure  that

main  voltage meet the requirements of the appliance. This information is available
on  a  label,  on  the  right  side  of  the  appliance,  as  you  face  it.

In  case  of

incongruence  or  if  in  doubt,  do  not  connect  the  apparatus.  Ask  for  the
equipment to be checked by specialized personnel.

NORTH

ovens  equipment  are  commercial grade  appliances  and  should,  there  for,

be used by personnel who are specially trained in their use.

 All  procedures  concerning  installation  and  connection  of  the  appliance  must  be

carried out exclusively by specialized technicians according to specifications valid in
the country where installation is taking place.

 Before any routine cleaning, disconnect from electricity mains. The same procedure

must  be  followed  in  case  of  malfunction  of  the  appliance,  while  waiting  for  the
service technician.

 Any repairs must be exclusively carried out by authorized personnel using

original

spare parts only.

 The  manufacturer  cannot  be  held  responsible  for  damage  caused  to  persons,

animals  or  property  due  to  misuse,  tampering,  unauthorized  modification,  or  uses
other than ones mentioned and / or considered in this manual.

Summary of Contents for CORFU

Page 1: ...ETA These appliances comply with requirements of E E C 73 23 CEE EN 60335 1 EN 60335 2 36 SOTIRIOS D PRODANAS PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANTS PATISSERIES SNACK BAR OFFICE FACTORY National road Kilkis Thessaloniki P C 611 00 TEL 30 23410 41819 FAX 30 23410 41539 P O BOX 400 70 P C 564 04 www north gr e mail info north gr ...

Page 2: ... 3 600 RHODES 760 780 645 4 800 CRETE 760 780 775 6 000 F80P 790 800 520 7 500 Chamber Dimensions MODEL LENGHT mm WIDTH mm HEIGHT mm F 80 F 80T 570 790 175 F 135 F 135T 1100 790 175 F 81T 600 810 195 F 136T 1100 810 195 F50 500 500 130X2 F65A 600 600 130 F70T 600 600 130X2 CORFU 480 620 130X2 RHODES 480 620 130X3 CRETE 480 620 130X4 F80P 550 610 130X2 Electrical Supply F 80 F 80T F65A F81T RHODES ...

Page 3: ...handles one for each door Hole for ventilation Ø30 mm for F 80 F 80T F 81T Ø50 mm regulated for F 135 F 135T F 136T Glass wool chamber insulation Electrical Components Wire heating elements F 80 F 80T 1 x 2 800 Watt bottom and 1 x 2 200 Watt above F 135 F 135T 2 x 3 600 Watt F 81T 1 x 2 800 Watt bottom and 1 x 2 200 Watt above F 136T 2 x 3 600 Watt F50 3x1 200 Watt F65A 1x2 000 Watt above bottom 1...

Page 4: ... incongruence or if in doubt do not connect the apparatus Ask for the equipment to be checked by specialized personnel NORTH ovens equipment are commercial grade appliances and should there for be used by personnel who are specially trained in their use All procedures concerning installation and connection of the appliance must be carried out exclusively by specialized technicians according to spe...

Page 5: ...BLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 6: ...ailable power supply connect the cables Single phase power supply HO7RNF 3x2 5 3x4 3x6 Remove the provided bridges and short circuit L1 L2 Connect the phase to L1 or L2 the neutral to 1 or 2 and earth to earth terminal F50 CORFU F80 F80T F81T RHODES CRETA F135 F135T F136T F80P b Two phases power supply HO7RNF 4x2 5 HO7RNF 4x4 Connect the phases to L1 L2 Connect the earth neutral to 1 or 2 Connect ...

Page 7: ...move the right side cover of the appliance Release the wires and remove the heating element holding screws inside chamber For the lower heating element remove the grill plate The lighting lamp is replaced from the inside of the chamber after removing lamp s lid For the thermostats indicating lamps and lighting switches remove the right side cover of the appliance CUT OFF THE POWER SUPPLY BEFORE CO...

Page 8: ...MENT ALL ASSEMBLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 9: ...elements will control the chamber s temperature picture 1 During operation indicating lamp is on For chamber s lighting set lighting switch to position 1 picture 2 For the ventilation of the chamber roll the operation knob at left side of the appliance picture 3 3 2 CLEANING AND MAINTENANCE Turn off the heating elements before any cleaning or maintenance procedures Let the appliance cool and make ...

Reviews: