ELECTRIC OVENS

SPECIFICATIONS

The tables below refer to the specifications of models F-80, F-80T, F-135, F-135T, F-
81T, F-136T, F50, F65A, F70T, CORFU, RHODES, CRETE, F80P.

Overall Dimensions

MODEL

LENGHT

(mm)

WIDTH

(mm)

HEIGHT

(mm)

POWER

(Watt)

F-80  /  F-80T

800

960

445

5.000

F-135 / F-135T

1350

960

445

7.200

F-81T

880

990

410

5.000

F-136T

1380

990

410

7.200

F50

680

610

450

3.600

F65A

880

750

380

4.500

F70T

880

750

630

9.000

CORFU

690

780

465

3.600

RHODES

760

780

645

4.800

CRETE

760

780

775

6.000

F80P

790

800

520

7.500

Chamber Dimensions

MODEL

LENGHT

(mm)

WIDTH

(mm)

HEIGHT

(mm)

F-80  / F-80T

570

790

175

F-135  / F-135T

1100

790

175

F-81T

600

810

195

F-136T

1100

810

195

F50

500

500

130X2

F65A

600

600

130

F70T

600

600

130X2

CORFU

480

620

130X2

RHODES

480

620

130X3

CRETE

480

620

130X4

F80P

550

610

130X2

Electrical Supply

F-80 / F-80T / F65A / F81T /
RHODES

: 230V  AC / 400V  2N  AC  50Hz

F50 / CORFU

: 230V  AC / 50Hz

F70T / CRETA / F80P / F135 /
F135T / F136T

: 230V  AC / 400V  3N  AC  50Hz

P  20

 60335-1

60335-2-36

CE

Main Parts

  DKP steel body, optionally AISI 430 stainless steel (F80, F80T, F81T, F135, F135T,

F136T).

Summary of Contents for CORFU

Page 1: ...ETA These appliances comply with requirements of E E C 73 23 CEE EN 60335 1 EN 60335 2 36 SOTIRIOS D PRODANAS PROFESSIONAL ELECTRIC GAS MACHINES FOR RESTAURANTS PATISSERIES SNACK BAR OFFICE FACTORY National road Kilkis Thessaloniki P C 611 00 TEL 30 23410 41819 FAX 30 23410 41539 P O BOX 400 70 P C 564 04 www north gr e mail info north gr ...

Page 2: ... 3 600 RHODES 760 780 645 4 800 CRETE 760 780 775 6 000 F80P 790 800 520 7 500 Chamber Dimensions MODEL LENGHT mm WIDTH mm HEIGHT mm F 80 F 80T 570 790 175 F 135 F 135T 1100 790 175 F 81T 600 810 195 F 136T 1100 810 195 F50 500 500 130X2 F65A 600 600 130 F70T 600 600 130X2 CORFU 480 620 130X2 RHODES 480 620 130X3 CRETE 480 620 130X4 F80P 550 610 130X2 Electrical Supply F 80 F 80T F65A F81T RHODES ...

Page 3: ...handles one for each door Hole for ventilation Ø30 mm for F 80 F 80T F 81T Ø50 mm regulated for F 135 F 135T F 136T Glass wool chamber insulation Electrical Components Wire heating elements F 80 F 80T 1 x 2 800 Watt bottom and 1 x 2 200 Watt above F 135 F 135T 2 x 3 600 Watt F 81T 1 x 2 800 Watt bottom and 1 x 2 200 Watt above F 136T 2 x 3 600 Watt F50 3x1 200 Watt F65A 1x2 000 Watt above bottom 1...

Page 4: ... incongruence or if in doubt do not connect the apparatus Ask for the equipment to be checked by specialized personnel NORTH ovens equipment are commercial grade appliances and should there for be used by personnel who are specially trained in their use All procedures concerning installation and connection of the appliance must be carried out exclusively by specialized technicians according to spe...

Page 5: ...BLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 6: ...ailable power supply connect the cables Single phase power supply HO7RNF 3x2 5 3x4 3x6 Remove the provided bridges and short circuit L1 L2 Connect the phase to L1 or L2 the neutral to 1 or 2 and earth to earth terminal F50 CORFU F80 F80T F81T RHODES CRETA F135 F135T F136T F80P b Two phases power supply HO7RNF 4x2 5 HO7RNF 4x4 Connect the phases to L1 L2 Connect the earth neutral to 1 or 2 Connect ...

Page 7: ...move the right side cover of the appliance Release the wires and remove the heating element holding screws inside chamber For the lower heating element remove the grill plate The lighting lamp is replaced from the inside of the chamber after removing lamp s lid For the thermostats indicating lamps and lighting switches remove the right side cover of the appliance CUT OFF THE POWER SUPPLY BEFORE CO...

Page 8: ...MENT ALL ASSEMBLY AND CONNECTION PROCEDURES TESTING AND REQUIRED REPAIRS MUST BE CARRIED OUT BY SPECIALIZED AND AUTHORIZED PERSONNEL ONLY NORTH ENTERPRISES CANNOT BE HELD RESPONSIBLE FOR ANY NEGATIVE CONSEQUENCES IN CASE OF INTERVENTIONS BY NON SPECIALIZED TECHNICAL PERSONNEL OR DUE TO NONCOMPLIANCE WITH FACTORY INSTRUCTIONS ...

Page 9: ...elements will control the chamber s temperature picture 1 During operation indicating lamp is on For chamber s lighting set lighting switch to position 1 picture 2 For the ventilation of the chamber roll the operation knob at left side of the appliance picture 3 3 2 CLEANING AND MAINTENANCE Turn off the heating elements before any cleaning or maintenance procedures Let the appliance cool and make ...