Installing Skid-Resistant Pads

Installing Between Two Walls

Step 1:

To help protect floors, ensure the skid-resistant pads are on 

the bottom of the gate panels. Clean and dry the panels prior 

to installing the pads. Remove a single pad from the release 

paper as shown in Figure 1. Place the adhesive side of the 

pad onto the bottom edge of the gate panel approximately 

2” from the center of each hinge, as shown in Figure 2. 

Repeat steps for each of the remaining pads. Maximum 

skid-resistance will be maintained by cleaning the bottoms 

of the pads periodically with a water-dampened clean cloth.

FIGURE 1

FIGURE 2

Page 3

Step 2:
Position both of the preassembled wall mounting 

connectors/wall hinges, vertically so the wall hinge 

pins are facing upwards on the wall, and the mounting 

connector is as close to the floor as possible. Mark the 

top of each wall hinge. See Figure 3.
Step 3:

Separate the mounting connectors from the wall 

hinges by pressing inward on the locking boss located 

in the center of the wall hinge. Lift up on the 

connectors to free them from the wall hinge. See 

Figure 4 for removal from wall hinge.
Step 4:

To attach the wall hinge to the wall, align the top with the 

mark drawn in Step 2. Mark the top hole and pre-drill a 

1/8” pilot hole. Attach the top of the wall hinge in place 

with a screw. Proceed down the hinge and install a screw 

into each screw hole with screws provided.
Step 5:

Attach the mounting connector side A to panel 1 by 

setting opening A over Pin B, push down in order to 

slide Pin C into the slot of Cylinder D. See Figure 5. 
Step 6:

Attach the mounting connector side B to panel 2 by 

setting opening A over Pin B, push down in order to 

slide Pin C into the slot of Cylinder D. See Figure 6. 

WARNING:

 Do not mount gate hinges into sheetrock or 

plaster. Hardware is included for use in solid materials, 

such as wood or metal. Never mount the gate at the top 

of the stairs.

Note: 

 This gate is to be used in openings 38.5” to 201” 

wide.  When setting up as a barrier, maximum number of 

panels is six.

FIGURE 3

FIGURE 4

FIGURE 5

FIGURE 6

Wall

Mark

Here

Wall

Mark

Here

Floor

Pin C

Pin B

Opening A

Opening A

Slot in 

Cylinder D

Slot in Cylinder D

Pin B

Pin C

FIGURE 7

Step 7:

Attach the mounting connectors, that are now 

attached to the panels, to the wall hinges by 

aligning the horseshoe shaped hoops on one 

side of the gate over the pins on the wall hinges 

to set the gate in place. See Figure 7.

NOTE: Always lift up on the end panels to 

ensure that the gate is properly secured and 

locked in place.

Removal from Wall Hinge

To remove the gate from the wall hinge, press on 

the locking boss located on the center of the wall 

hinge (See Figure 8), and lift the panel itself until 

the gate rib clears the locking boss.

FIGURE 8

Wall

Hinge

Summary of Contents for 8671

Page 1: ...TANT PLEASE KEEP FOR FUTURE REFERENCE For helpful tips and instructions please visit our website www northstatesind com or contact our Customer Care department via email CustomerService northstatesind...

Page 2: ...to keep child away from pool This product will not necessarily prevent all accidents NEVER leave child unattended This product intended for use with children from 6 months up to 24 months of age Perio...

Page 3: ...of the wall hinge in place with a screw Proceed down the hinge and install a screw into each screw hole with screws provided Step 5 Attach the mounting connector side A to panel 1 by setting opening...

Page 4: ...to expand the size of your enclosure from 18 5 square feet to 34 4 square feet The extension is installed by following the Installation as a Freestanding Enclosure that appear above To disconnect two...

Page 5: ...Para obtener consejos tiles e instrucciones visite nuestro sitio web www northstatesind com o Comun quese con nuestro Departamento de Atenci n al Cliente por correo electr nico CustomerService northst...

Page 6: ...s como puntos de apoyo o constituir un peligro de asfixia o estrangulaci n No utilice los montajes de pared con el panel para puerta con marco en U que se encuentra en los modelos 8651 8750 8751 8752...

Page 7: ...n hacia arriba en la pared y que el conector de montaje est tan cerca del piso como sea posible Marque la parte superior de cada bisagra de pared Vea Figura 3 Separe los conectores de montaje de las b...

Page 8: ...pies cuadrados 3 2 metros cuadrados La extensi n se instala siguiendo las indicaciones de la Instalaci n a modo de cerco independiente que aparece arriba FIGURA 13 PANEL 1 PANEL 2 PasadodrC AberturaD...

Page 9: ...ants de 6 24 mois IMPORTANT CONSERVER POUR CONSULTATION ULT RIEURE Pour des conseils et des instructions utiles s il vous pla t visitez notre site Web www northstatesind com ou Contactez notre service...

Page 10: ...illerie comprise ne convient que pour les mat riaux solides comme du bois ou du m tal NE JAMAIS rien laisser dans le Superyard qui pourrait servir de marche pied ou pr senter un risque d touffement ou...

Page 11: ...e des vis fournies dans chacun des trous de vis de la charni re tape 5 Fixez le c t A du connecteur de montage au panneau 1 en pla ant l ouverture A sur la fiche B puis en appuyant vers le bas pour gl...

Page 12: ...lle de votre enceinte passant de 18 5 pi2 34 4 pi2 1 7 m2 3 2 m2 L extension est install e en suivant les instructions d installation en tant qu enceinte ci dessus Votre enceinte est fabriqu e partir...

Reviews: