![North Ridge Pumps seepex BN Series Operating And Maintenance Instructions Manual Download Page 39](http://html1.mh-extra.com/html/north-ridge-pumps/seepex-bn-series/seepex-bn-series_operating-and-maintenance-instructions-manual_1707791039.webp)
Operating Instruction
Single-Acting Mechanical Seal
Dokument
document
Blatt
sheet
Ausgabe
issue
OM.SEA.02e
2 (2)
A / 10.02.95
7.2
Reassembly
ATTENTION
Mechanical seals are precision parts of high quality.
Therefore, the installation must be effected with care.
Gentle handling and extreme neatness are essential.
- Clean mechanical seal housing (333)
- Evenly press counter-ring with o-ring into mecha-
nical seal housing (333). To facilitate assembly, the
o-ring should be moistened with a lubricant (diluted
fluid soap).
ATTENTION
- Oil or grease must not be used to facilitate
assembly.
- Install mechanical seal housing (333) to lantern
(200) and onsure correct position of flushing
connections.
- Remove plug-in shaft (307), burrs and roughness
and clean the unit.
- Check / adjust set dimension of mechanical seal on
plug-in shaft (307). Moisten plug-in shaft (307) and
elastomer parts of mechanical seal with lubricant
(diluted fluid soap).
- Slip mechanical seal onto plug-in shaft (307) as far
as set ring.
- Lubricate drive shaft (ANT) with antiseize graphite
petroleum.
- Moisten splash ring (310) and plug-in shaft (307)
with pin joint grease, (for type, please see index) and
slip splash ring (310) onto output shaft of drive. Note
installating position of splash ring and refer to
description on splash ring.
- Move rotating unit (RTE) through mechanical seal
housing (333) and splash ring (310) and slip splash
ring (310) onto output shaft of drive (ANT). Push in
plug-in shaft pin (309) in horizontal position.
- Position of splash ring:
Collar of splash ring shall be fitted in a distance of
about 0.5 mm to lantern (200).