8
3.3 Refrigeration circuit drawing of inverter binary type
Indoor Unit
Cross
flow fan
Ev
apora
to
r
Liquid valve A
Liquid valve B
Gas valve B
Gas valve A
EXVA
EXVB
Axial
flow fan
Condenser
Compressor
4-way
valve
Auxiliary
Capillary
Capillary A
Capillary B
Exhaust
temp. sensor
Indoor pipe out
temp. seneor A
Indoor pipe out
temp. seneor B
Filter A
Filter B
Outdoor Unit
Main
Capillary
Check
Valve
Coil temp.
sensor
4 Temperature Operation range
Cooling mode
Indoor temperature
≥
17
℃
Outdoor temperature
0
℃~
50
℃
Heating mode
Indoor temperature
≤
30
Outdoor temperature
-15
℃~
24
℃
Dry mode
Indoor temperature
>
10
℃
Outdoor temperature
0
℃
~
43
℃
Liquid valve A
Gas valve C
EXV C
4-way
valve
Compressor
Condenser
Axial
flow fan
EXV B
EXV A
Gas valve A
Gas valve B
Liquid valve C
Liquid valve B
Evaporator
Cross
flow fan
Indoor Unit
Capillary A
Capillary B
Capillary C
Filter A
Filter B
Filter C
Main
Capillary
Auxiliary
Capillary
Check
Valve
Exhaust
temp. sensor
Indoor pipe out
temp. seneor B
Indoor pipe out
temp. seneor A
Indoor pipe out
temp. seneor C
Outdoor Unit
Coil temp.
sensor