20
7.13.3Timer off: the A/C will be automatically off at the set time
7.13.4Timer on/off function: if Timer on & Timer off functions have been set at the same
time, the A/C will act on which the timer achieves earlier.
.
7.14Sleep mode
7.14.1It is available at cooling, heating or auto mode.
7.14.2 Cooling:
The set temperature rise 1
℃
per hour. Two hours later, the set temperature will
maintain as a constant and the fan speed is kept at low speed.
7.14.3 Heating:
The set temperature decrease 1
℃
per hour. Two hours later, the set temperature
will maintain as a constant and the air circulation is kept at low speed (Cold air
proof function takes precedence over all).
7.14.4 Auto:
The Sleep Mode running function operates in accordance with selected running mode by
auto mode.
7.14.5 After 7 hours, unit cancels this mode automatically, and the unit turns off.
7.14.6 Auto restart function
In case of a sudden power failure, this function automatically sets the unit to
previous settings before the power failure when power returns.
7.15 Mode conflict
The indoor units can not work cooling mode and heating at same time.
Heating mode has a priority.
7.15.1Definition
Cooling mode
Heating Mode
Fan
Off
Cooling mode
No
Yes
No
No
Heating Mode
Yes
No
Yes
No
Fan
No
Yes
No
No
Off
No
No
No
No
No: No mode conflict;
Yes: Mode conflict
7.15.2 Unit action
In case of one Indoor unit working in cooling mode or fan mode, and another indoor unit
is set to heating mode, the indoor unit working in cooling mode or fan mode will
change to stand by. The outdoor unit will work in heating mode.
In case of one Indoor unit working in heating mode, and another indoor unit is set to
cooling mode or fan mode, the indoor unit setting to cooling mode or fan mode will
change to stand by.
8.Troubleshooting