Page 62 of 290
NT1R20 Off-Premise Station Analog Line Card
553-3001-105
Standard 5.00
June 1999
Ringer limitations
The OPS line card supports up to three NE-C4A (3 REN) ringers on each line
for either ONS or OPS applications. This is shown in Table 9.
Environmental specifications
Table 10 shows the environmental specifications of the card.
Table 9
OPS analog line card—ringer limitations
ONS Loop Range
Maximum Number of
Ringers (REN)
0–10 ohms
3
> 10–460 ohms
2
OPS Loop Range
Maximum Number of
Ringers (REN)
0–10 ohms
3
> 10–900 ohms
2
> 900–2300 ohms
1
Table 10
OPS analog line card—environmental specifications
Parameter
Specifications
Operating temperature
0° to +60° C (+32 to +140° F),
ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
–40° to +70° C (–40° to +158° F)