![Nortel NT1R20 Description Download Page 110](http://html1.mh-extra.com/html/nortel/nt1r20/nt1r20_description_1707064110.webp)
Page 86 of 290
NT5D11 Line-side T1 Interface Card
553-3001-105
Standard 5.00
June 1999
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided on
the line-side T1 card. It does, however, have protection against accidental
shorts to –52 V dc analog lines.
When the card is used to service off-premise terminal equipment through the
public telephone network, install a channel service unit (CSU) as part of your
terminal equipment to provide external line protection.
Environmental specifications
Table 17 shows the environmental specifications of the line-side T1 card.
Table 17
Line-side T1 card—environmental specifications
Parameter
Specifications
Operating temperature-normal
15° to +30° C (+59° to 86°F), ambient
Operating temperature-short term
10° to +45° C (+50° to 113°F), ambient
Operating humidity-normal
20% to 55% RH (non-condensing)
Operating humidity-short term
20% to 80% RH (non-condensing)
Storage temperature
–50° to +70° C (–58° to 158°F), ambient
Storage humidity
5% to 95% RH (non-condensing)
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......