Page 174 of 290
NT5D33 and NTRB34 Line-side E1 Interface Cards
553-3001-105
Standard 5.00
June 1999
When entering the
Set Alarm (S A)
command, the MMI will scroll
through the previously described series of alarm options. These options will
be displayed along with their current value, at which point you can enter a
new value or enter a
<CR>
to retain the current value. Table 46 outlines the
options available in the
Set Alarm (S A)
function.
Note: If the duration period set is too long, the Line-side E1 card will be
slow to return to service automatically even when the carrier is no longer
experiencing errors. The
CLEAR ALARM (C A)
command will have
to be entered manually to restore service promptly. To avoid this, an
alarm’s duration period should normally be set to 10 seconds.
Table 46
Set alarm options
Option
Description
AL1 Threshold
Sets the allowable bit errors per second before
alarm level 1 is activated. Factory default is 6.
AL1 Duration
Sets the duration in seconds (from 1 to 3,600
seconds) that alarm level 1 is activated. Factory
default is 10 seconds.
AL2 Threshold
Sets the allowable bit errors per second (from 3 to
9) before alarm level 2 is activated. Factory default
is 10
-5.
AL2 Duration
Sets the duration in seconds (from 1 to 3,600
seconds) that alarm level 2 is activated. Factory
default is 10 seconds.
Frame Slip Threshold
Sets the allowable frame slips per time period (from
1 to 255) before alarm level 2 is activated. Factory
default is 5.
Frame Slip Duration
Sets the duration in hours (from 1 to 24) that the
frame slips are counted. After this time period, the
counter is reset to 0. Factory default is 2 hours.
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......