NT8D02 Digital Line Card
Page 207 of 290
Line cards
Description
Power requirements
The digital line card pr15 V dc over each loop at a maximum current
of 80 mA. It re15 V, -15 V, and +5 V from the backplane. One
NT8D06 Peripheral Equipment Power Supply AC or NT6D40 Peripheral
Equipment Power Supply DC can supply power to a maximum of 16 digital
line cards.
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided on
the digital line card. The digital line card does, however, have protection
against accidental shorts to -52 V dc analog lines.
When the card is used to service off-premise telephones, primary and
secondary main distribution frame (MDF) protection must be installed.
Details on installing protection devices are given in “Off-premise line
protection” on page 48. Off-premise telephones served by cable pairs routed
through the central office, or crossing a public right-of-way, can be subject to
a requirement for on-card protection, and MDF protectors may not be
acceptable. Check local regulations before providing such service.
Table 52
Digital line card—power required
Voltage
Current (max.)
±5.0 V dc
150 mA
+15.0 V dc
1.6 Amp
–15.0 V dc
1.3 Amp
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......