Page 120 of 290
NT5D11 Line-side T1 Interface Card
553-3001-105
Standard 5.00
June 1999
Clear Alarm
The Clear Alarm (C A) command set will clear all activity initiated by an
alarm: the external alarm hardware will be deactivated (the contact normally
open will be reopened), the LED light will go out, an entry will be made in
the alarm log of the date and time the alarm was cleared, and line processing
will cease (for alarm level 2 only). When this command set is typed in, the
MMI will display the message “Alarm acknowledged.” If the alarm condition
still exists, the alarm will be declared again.
Display Alarms
A detailed report of the most recent 100 alarms with time and date stamps can
be displayed by entering the Display Alarms (D A) command set into the
MMI. Entering the Display Alarms (D A) command set will cause a screen
similar to the following to appear:
The Pause command can be used to display a full screen at a time by entering
D A P.
Clear Alarm Log
You can clear all entries in the alarm log by typing in the Clear Alarm Log
(C A L) command set.
Alarm Log
3/03/95 1:48 Yellow alarm on T1 carrier
3/03/95 1:50 Initialized Memory
3/03/95 2:33 T1 carrier level 1 alarm
3/03/95 3:47 T1 carrier level 2 alarm
3/03/95 4:43 T1 carrier performance within thresholds
3/03/95 15:01 Log Cleared
Summary of Contents for NT1R20
Page 2: ......
Page 4: ...iv 553 3001 105 Standard 5 00 June 1999 iv ...
Page 12: ...xii Contents 553 3001 105 Standard 5 00 June 1999 ...
Page 76: ...Page 52 of 290 Description 553 3001 105 Standard 5 00 June 1999 ...
Page 154: ...Page 130 of 290 NT5D11 Line side T1 Interface Card 553 3001 105 Standard 5 00 June 1999 ...
Page 276: ...Page 252 of 290 QPC452 Basic 500 2500 Analog Line Card 553 3001 105 Standard 5 00 June 1999 ...
Page 306: ...Page 282 of 290 List of terms 553 3001 105 Standard 5 00 June 1999 ...
Page 314: ...Page 290 of 290 553 3001 105 Standard 5 00 June 1999 ...
Page 315: ......