Chapter 2 Network configuration
59
Using the BayStack 380 10/100/1000 Switch
In
Figure 14
, tagged incoming packets are assigned directly to VLAN 2 because
of the tag assignment in the packet. Port 5 is configured as a tagged member of
VLAN 2, and port 7 is configured as an untagged member of VLAN 2.
Figure 14 802.1Q tag assignment
As shown in
Figure 15
, the tagged packet remains unchanged as it leaves the
switch through port 5, which is configured as a tagged member of VLAN 2.
However, the tagged packet is stripped (untagged) as it leaves the switch through
port 7, which is configured as an untagged member of VLAN 2.
Figure 15 802.1Q tagging (after 802.1Q tag assignment)
Port 6
DA
SA
Tag
Data
CRC
Tagged packet
BS45013A
Port 7
Port 8
Port 1
Po
rt
4
Po
rt
5
Port 2
Port 3
802.1Q Switch
PVID = 2
Untagged member
of VLAN 2
Tagged member
of VLAN 2
Before
BS45014A
Port 6
Port 7
Port 8
Port 1
Po
rt
4
Po
rt
5
Port 2
Port 3
802.1Q Switch
Key
Priority
CFI
VID
- User_priority
- Canonical format indicator
- VLAN identifier
PVID = 2
Tagged member
of VLAN 2
Untagged member
of VLAN 2
After
DA
SA
Data
CRC*
(*Recalculated)
Outgoing
untagged packet
changed
(tag removed)
DA
SA
Data
CRC
Tag
VID = 2
Priority
16 bits
3 bits
1 bit
12 bits
8100
CFI
Summary of Contents for BayStack 380
Page 6: ...6 212859 A ...
Page 12: ...12 Contents 212859 A ...
Page 16: ...16 Figures 212859 A ...
Page 24: ...24 Preface 212859 A ...
Page 48: ...48 Chapter 1 BayStack 380 Switch 212859 A ...
Page 92: ...92 Chapter 2 Network configuration 212859 A ...
Page 178: ...178 Chapter 4 Troubleshooting 212859 A ...
Page 198: ...198 Appendix B Installing SFP and CWDM Gigabit Interface Converters GBICs 212859 A ...
Page 210: ...210 Appendix E Default settings 212859 A ...
Page 218: ......