86
Configure an E1/T1 card
Prompt
Response
Description
YALM
FDL, DG2
Yellow alarm method.
TRSH
0 - 15
Threshold.
...
...
--End--
Procedure 17 “Configuring PRI2 loops using LD 17” (page 86)
describes
the configuration in LD 17 to support PRI2/E1 loops (common equipment
parameters) on the PRI Gateway.
Procedure 17
Configuring PRI2 loops using LD 17
Step
Action
1
Log on to the CS 1000E.
2
To access LD 17, enter:
LD 17
3
Enter the responses shown in
Table 17 "PRI2 loop configuration
Table 17
PRI2 loop configuration (LD 17)
Prompt
Response
Description
REQ
CHG
Change existing data.
TYPE
CEQU
Make changes to common equipment parameters.
CFN
YES
Common equipment.
...
PRI2
loop
Digital loop (2.0 Mb) (0 - 254)
MG_CARD
supl sh card
The physical card for the PRI2 loop association to the
PRI Gateway.
The format is superloop, shelf, card.
For the PRI Gateway, card 1 to 8 is applicable.
--End--
Procedure 18 “Configuring DPNSS/DASS loops using LD 17” (page
87)
shows the configuration in LD 17 needed to support DPNSS loops
(common equipment parameters) on the PRI Gateway.
Nortel Communication Server 1000
Media Gateway 1000E PRI Gateway Installation and Commissioning
NN43041-311 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.
Summary of Contents for 1000E PRI