DC Inverter U-match Series Floor Ceiling Type Unit
9
4.1.3 Indoor Unit Installation
(1). Determine the location of the hanger with the paper template, and then
remove the paper template.
Fig. 4.2
(2). Insert the anchor bolts into the drilled holes, and drive the pins completely
into the anchor bolts with a hammer.
(3). Remove the right and left side panels.
(4). Put the hanger bolt into the clasp of the indoor unit and tighten screws on
the hanger to prevent the indoor unit from moving.
(5). Reinstall and secure the right and left side panels.
ƹ
Floor type
Fig. 4.3