DC Inverter U-match Series Floor Ceiling Type Unit
5
3.2.2 Outdoor Unit
ķ
. Install the unit where it will not be tilted by more than 5°.
ĸ
.
The outdoor unit should be securely mounted to withstand high wind.
If possible, do not install the unit where it will be exposed to direct sunlight. (If
necessary, install a blind that does not interfere with the air flow.)
(1). Install the outdoor unit in a place where it will be free from dirt or rain as
much as possible.
(2). Install the outdoor unit where it is convenient to connect with the indoor
unit.
(3). Install the outdoor unit where the condensate water can be drained out
freely during heating operation.
(4). Do not place animals and plants in the path of the warm air.
(5). Select a location where sound and vibration will have little or no impact.
(6). Check the support structure to verify that it has sufficient load-carrying
capacity to support the weight of the unit. Mount the unit securely to reduce
vibration noise.
(7). Provide the space shown in Fig. 3.2, so that the air flow is not blocked. Also
for efficient operation, leave three of four directions of peripheral
constructions open.
Fig. 3.2
3.3 Pipe Connection Requirement
The maximum length of the connection pipe is listed in the Table below. Do not place the units
where the distance exceeds the maximum length of the connection pipe.