56
Lighting Instructions
This water heater does not have a pilot. It is equipped with an ignition device that automatically lights
the burner.
Do not try to light the burner by hand.
1. Read the safety information in the installation manual or on the front of the water heater.
2. Turn off all electrical power to the unit.
3. Do not attempt to light the burner by hand.
4. Turn the gas control manual valve (external to the unit) clockwise to the off position.
5. Wait five minutes to clear out any gas. If the smell of gas remains, stop, and follow the instructions
on page 3 of this manual.
6. Turn the gas control manual valve counterclockwise to the on position.
7. Turn on electric power to the unit.
8. The unit will now operate whenever hot water is called for. If the unit will not operate, follow the
shutdown instructions and call a service technician.
Shutdown Instructions
1. Stop any water demand.
2. Turn off electric power.
3. Turn the gas control manual valve clockwise to the off position.
Should overheating occur, or the gas supply fail to shut off, turn off the manual control valve to the appliance.
Handling after trial operation
• If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of
the water out of the unit and the plumbing system to prevent the unit and system from
freezing, and bleed the gas out of the gas line.
Freezing is not covered by the warranty.
15.
Dimensions
N-084M
Caution
(VIEW FROM TOP)
61mm (2.4")
140mm (5.5")
175mm (6.9")
102mm (4")
94mm (3.7")
239mm (9.4")
10mm (0.4")
BOTTOM OF CASE
56mm (2.2")
50mm (2")
43mm (1.7")
BOTTOM
OF CASE
615mm (24.2")
71mm (2.8")
WATER DRAIN VALVES
WIRING THROUGHWAYS
WATER DRAIN VALVES
COLD WATER INLET
GAS INLET
HOT WATER OUTLET
173mm (6.8")
AIR INLET
LED
FLUE COLLAR
89mm (3.5")
450mm (17.7")
465mm (18.3")
(WATER FILTER)
WATER DRAIN VALVE
35.5mm (1.4")
99mm (3.9")
140mm
(5.5")
170mm (6.7")
71mm(2.8")
35.5mm(1.4")
71mm (2.8")
99mm (3.9")
140mm
(5.5")
170mm (6.7")
86mm (3.4")
10mm (0.4")
450mm (17.7")
WIRING THROUGHWAYS
COLD WATER INLET (3/4")
HOT WATER OUTLET (3/4")
71mm (2.8")
GAS INLET (3/4")
UPPER WALL MOUNT BRACKETS
LOWER WALL MOUNT BRACKETS
665mm (26.2
")
41mm (1.6")
HOT
GAS
GROUND
COLD
360mm (14.2")
279mm (11")
244mm (9.6")
178mm (7")
N084M(46̲57)̲e.p65
05.11.28, 4:15 PM
Page 56
Adobe PageMaker 6.5J/PPC
Summary of Contents for N-084M-CA
Page 65: ...65 SAR8209 1 062 067 E J p65 06 1 12 8 16 AM 65...
Page 66: ...66 N084M 62 67 e p65 05 11 28 4 15 PM Page 66 Adobe PageMaker 6 5J PPC...
Page 67: ...67 N084M 62 67 e p65 05 11 28 4 15 PM Page 67 Adobe PageMaker 6 5J PPC...
Page 132: ...65 SAR8198 1 062 067 F E J p65 06 1 12 7 53 AM 65...
Page 133: ...66 SAR8198 062 067 F E J p65 05 11 28 3 29 PM Page 66 Adobe PageMaker 6 5J PPC...
Page 134: ...67 SAR8198 062 067 F E J p65 05 11 28 3 29 PM Page 67 Adobe PageMaker 6 5J PPC...