45
Vertical Vent Termination
Appliance
Adapter
Firestop
Firestop/
Support
Roof
Flashing
Rain
Cap
Hanger
Strap
Elbow
Condensation
Drain (Install
According to
Local Codes)
0.9m
(3')
Max.
• Terminate at least1.8m( 6') from
the combustion air intake of any
appliance, and 0.9m(3') fromany
other building opening, gas
utility meter, serviceregulatoretc.
• Enclose exterior vent systems
below the roof line to limit
condensation and protect
against mechanical failure.
• When the vent penetrates a
floor or ceiling and is not
running in a fire rated shaft, a
firestop and support is required.
• Terminate the vent system at
least 0.9m(3') above, but not
more than 1.8m(6') above the
roof line, or according to the
vent pipe manufacturer's in-
structions.
• Provide vertical support every
3.7m(12') or as required by the
vent pipe manufacturer's in-
structions.
• Slope the horizontal vent 1/4"
down wards for every
305mm(12").
• Do not vent straight upwards.
Always have a horizontal section
of venting.
• Install a condensation drain in
the horizontal section of the
venting.
N084M(35̲45)̲e.p65
05.11.28, 4:15 PM
Page 45
Adobe PageMaker 6.5J/PPC
Summary of Contents for N-084M-CA
Page 65: ...65 SAR8209 1 062 067 E J p65 06 1 12 8 16 AM 65...
Page 66: ...66 N084M 62 67 e p65 05 11 28 4 15 PM Page 66 Adobe PageMaker 6 5J PPC...
Page 67: ...67 N084M 62 67 e p65 05 11 28 4 15 PM Page 67 Adobe PageMaker 6 5J PPC...
Page 132: ...65 SAR8198 1 062 067 F E J p65 06 1 12 7 53 AM 65...
Page 133: ...66 SAR8198 062 067 F E J p65 05 11 28 3 29 PM Page 66 Adobe PageMaker 6 5J PPC...
Page 134: ...67 SAR8198 062 067 F E J p65 05 11 28 3 29 PM Page 67 Adobe PageMaker 6 5J PPC...