35
Gas Supply Piping
Cold Water Supply
Hot Water
Quick Connect Cord
Connector on PCB
G
Distance on sides
2 - 18 in. (50 - 457mm)
Distance at center : 18 - 36 in. (459 - 916mm)
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
Pressure
Relief Valve
Shutoff Valve
Gas Valve
Union
Hot Water
Cold Water
Size the piping to allow for the
maximum flow rates of the units.
The backflow preventer is
put up before it diverges.
Quick Connect Cord
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases
.
Quick Connect
System Diagram
Typical Plumbing
The Quick Connect Cord is 6 ft.(1.8m) long. Install the units 2-18” (50 - 457mm) apart from each other to ensure the
cable will be able to reach between the units. (See Typical Plumbing diagram). (If the distance between the two units is
too great, not only the cable won’t be able to reach, but the water temperature may also become unstable because of
the difference in pipe length between the two units).
ㆍ
Quick Connect Multi System cannot allows more than 2 units.
ㆍ
All units within Quick Connect Multi System must be of the same model.
ㆍ
Different models cannot work as Quick Connect Multi System.
• Insulate the hot water piping to prevent
heat loss. Insulate and apply heating
materials to the cold water supply piping
to prevent heat loss and freezing of
pipes when exposed to excessively cold
temperatures.
Chapter 4. – Installation
4-9. Quick Connect Multi System Installation
The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord.