34
Setting the Control Panel
Chapter 4. – Installation
Setting the Control Panel. (High Elevation)
To set the High Elevation
1. Turn off the power to the control panel. Press and hold the
‘Function Button’ for approximately 5 seconds to get into the
‘Installer mode’.
2. In ‘Installer Mode,’ turn the dial button clockwise until the
display reads ‘[5:EL]’.
3. ‘0-2’ will flash when the dial button is pressed. (The default
setting is ‘0-2’ for installations at 0-1,999 ft elevation)
4. Turn the dial button clockwise to select the value that corre-
sponds to the installation elevation.
5. Press the dial button to store the current setting and return
back to ‘Installer mode’.
Elevation above Sea Level
5:EL setting
0 ~ 1,999 ft (0 ~ 609 m)
0 - 2
2,000 ~ 4,999 ft (610 ~ 1,523 m)
2 - 5
5,000 ~ 7,999 ft (1,524 ~ 2,438 m)
5 - 8
8,000 ~ 10,000 ft (2,439 ~ 3,048 m)
8 - 10