![Nordstrom MiniCure 7119745C Product Manual Download Page 34](http://html1.mh-extra.com/html/nordstrom/minicure-7119745c/minicure-7119745c_product-manual_1704582034.webp)
Operation
5-2
Part 7119745C
E
2007 Nordson Corporation
MiniCure 08-07
NOTE:
If any of the above Indicators are NOT illuminated, it could indicate
a fault is present on your system. Inform your electrician or contact
Nordson UV for advice.
WARNING:
If this is the first time the unit has been switched on after
installation or the Earth Leakage has not been tested within the previous 24
hours, press the Earth Leakage Test Button
NOW. The isolator
should immediately switch off cutting all power. If the isolator or any
indicators remain on, then it could indicate a SERIOUS fault is present on
your system. Inform your electrician or contact Nordson UV for advice
immediately.
Starting the conveyor
Check:
S
The ’lamp’
switch is in the
OFF
position (out).
S
The ’high power’
switch is in the
ON
position (pressed in).
Press the ’conveyor start’
switch and hold in until the ’No Airflow’
indicator goes out. The main cooling fan and the conveyor should start to
work.
CAUTION:
Confirm visually that the conveyor belt is running.
Set the conveyor speed using the 10 turn dial on the control panel. Once
set the position can be locked using the small lever on the edge of the dial.
WARNING:
Caution when operating the conveyor belt continuously at very
low speed with the lamp on High Power. Where possible, adjust speed to a
minimum of 2 on the dial. This will prevent the possibility of the belt
overheating. It is recommended that the operator is present at all times
during operation.
Press the ’lamp on’
switch and the UV lamp will ignite. The power
% indicator meter will show a high power reading (approximately 150%).
When the lamp has ’burnt--in’ the power % meter will show approximately
100%. This will take approximately 90 secs.
When the lamp has ’burnt--in’ it can be switched to the lower power setting
by releasing the ’high power’
switch. The power meter should be
registering a reduced reading (approximately 65%).
Summary of Contents for MiniCure 7119745C
Page 4: ...Introduction O 2 E 2002 Nordson Corporation UV_CONG_EN_B 0802...
Page 8: ...This page intentionally let blank...
Page 54: ...This page intentionally let blank...
Page 57: ......
Page 58: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ...This page intentionally let blank...
Page 66: ...Drawings 9 2 Part 7119745C E 2007 Nordson Corporation MiniCure 08 07 Circuit Diagrams 60Hz...
Page 67: ......
Page 68: ......
Page 69: ......