![Nordstrom MiniCure 7119745C Product Manual Download Page 25](http://html1.mh-extra.com/html/nordstrom/minicure-7119745c/minicure-7119745c_product-manual_1704582025.webp)
Safety
1-15
Part 7119745C
E
2007 Nordson Corporation
MiniCure 08-07
U.V. Permissible Exposure Levels
Permissible Ultra Violet Exposures As Recommended By The
American Conference Of Government And Industrial Hygienists
Duration of Exposure
(per day)
Effective Irradiance
E Micro Watts/cm sq.
8 hours
0.1
4 hours
0.2
2 hours
0.4
1 hour
0.8
30 minutes
1.7
15 minutes
3.3
10 minutes
5.0
5 minutes
10
1 minute
50
30 seconds
100
10 seconds
300
1 second
3000
0.5 seconds
6000
0.1 seconds
30000
Permissible exposure time in seconds for exposure to actinic ultra-violet
radiation incident upon the unprotected skin or eye may be determined with
reference to table above, which provides exposure times corresponding to
effective irradiance in micro watts/cm sq.
Action in the Event of a Malfunction
If a system or any equipment in a system malfunctions, shut off the system
immediately and perform the following steps:
S
Disconnect and lock out electrical power.
S
Identify the reason for the malfunction and correct it before restarting the
equipment.
Disposal
Dispose of equipment and materials used in operation and servicing
according to local codes.
Summary of Contents for MiniCure 7119745C
Page 4: ...Introduction O 2 E 2002 Nordson Corporation UV_CONG_EN_B 0802...
Page 8: ...This page intentionally let blank...
Page 54: ...This page intentionally let blank...
Page 57: ......
Page 58: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ...This page intentionally let blank...
Page 66: ...Drawings 9 2 Part 7119745C E 2007 Nordson Corporation MiniCure 08 07 Circuit Diagrams 60Hz...
Page 67: ......
Page 68: ......
Page 69: ......