Safety
1-3
Part 7119745C
E
2007 Nordson Corporation
MiniCure 08-07
Personal Safety
To prevent injury follow these instructions.
S
On a daily basis the Earth Leakage Circuit Breaker and the combined
Isolator (at the connection box) should be tested.
S
This is carried out by pressing the ’Test’
button while the
system is switched on -- the Isolator should switch off instantly.
WARNING:
If the isolator or any indicator remains on, then it could indicate
that a SERIOUS fault is present on your system. Inform your electrician or
contact Nordson UV for advice immediately.
NOTE:
To protect the Earth Leakage Sensor, this test function will only
work while the lamps are switched off.
WARNING:
NEVER LOOK AT A LIGHTED LAMP
S
ULTRA--VIOLET RADIATION IS HARMFUL TO EYES AND CAN
BE HARMFUL TO SKIN. ALWAYS WEAR SUITABLE
PROTECTION WHEN USING THIS SYSTEM.
S
THIS SYSTEM IS DESIGNED TO BE USED FOR HAND FED
OPERATION, SPECIAL UV SAFETY GLASSES & GLOVES MUST
BE WORN.
Suitable glasses (Part No. 7350033) and gloves (Part No. 7350657) are
supplied with the unit, additional pairs are available from Nordson UV.
S
Do not operate or service equipment unless you are qualified.
S
Do not operate equipment unless safety guards, doors, or covers are
intact and automatic interlocks are operating properly. Do not bypass or
disarm any safety devices.
S
Keep clear of moving equipment. Before adjusting or servicing any
moving equipment, shut off the power supply and wait until the
equipment comes to a complete stop. Lock out power and secure the
equipment to prevent unexpected movement. Wait 2 mins for the lamp
to cool down.
S
If you receive even a slight electrical shock, shut down all electrical
equipment immediately. Do not restart the equipment until the problem
has been identified and corrected.
S
Obtain and read Material Safety Data Sheets (MSDS) for all materials
used. Follow the manufacturer’s instructions for safe handling and use
of materials, and use recommended personal protection devices.
S
To prevent injury, be aware of less-obvious dangers in the workplace
that often cannot be completely eliminated, such as hot surfaces, sharp
edges, energized electrical circuits, and moving parts that cannot be
enclosed or otherwise guarded for practical reasons.
Summary of Contents for MiniCure 7119745C
Page 4: ...Introduction O 2 E 2002 Nordson Corporation UV_CONG_EN_B 0802...
Page 8: ...This page intentionally let blank...
Page 54: ...This page intentionally let blank...
Page 57: ......
Page 58: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ...This page intentionally let blank...
Page 66: ...Drawings 9 2 Part 7119745C E 2007 Nordson Corporation MiniCure 08 07 Circuit Diagrams 60Hz...
Page 67: ......
Page 68: ......
Page 69: ......