![Nordstrom MiniCure 7119745C Product Manual Download Page 21](http://html1.mh-extra.com/html/nordstrom/minicure-7119745c/minicure-7119745c_product-manual_1704582021.webp)
Safety
1-11
Part 7119745C
E
2007 Nordson Corporation
MiniCure 08-07
Safety UV curing
NOTE:
The subtrate collection tray on the outfeed of the unit forms part of
the UV shielding. If this tray is not fitted alternative shielding methods must
be provided for operator and bystander safety.
UV measurements in the infeed chamber at belt level are
20 Micro Watts/cm
2
. If gloves and glasses are not used, then exposure to
the UV should be limited to no more than 4 mins per day.
UV measurements in the delivery tray are between
0.8--1.0 Micro Watts/cm
2
.
U.V. Radiation
UV radiation is generated from UV lamps and can be harmful if operator
exposure exceeds recommended levels, (see
U.V. Permissible Exposure
Levels
in this section).
Radiation is in the wavelength bands A B and C. Exposure to UV radiation
can result in:
S
Reddening of skin.
S
Headaches
S
Sore eyes
If any symptoms appear, investigations should be carried out.
Nordson UV can, on request, supply UV safety glasses -- Part No. 7350033
and gloves -- Part No. 7350657.
First Aid
On skin no treatment can immediately be made, however, soothing cream
can be applied to the affected area.
For exposure to eyes medical attention should be sought immediately.
Summary of Contents for MiniCure 7119745C
Page 4: ...Introduction O 2 E 2002 Nordson Corporation UV_CONG_EN_B 0802...
Page 8: ...This page intentionally let blank...
Page 54: ...This page intentionally let blank...
Page 57: ......
Page 58: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ...This page intentionally let blank...
Page 66: ...Drawings 9 2 Part 7119745C E 2007 Nordson Corporation MiniCure 08 07 Circuit Diagrams 60Hz...
Page 67: ......
Page 68: ......
Page 69: ......