OBSOLETE
Model SCF-M1 Handgun
19
1997 Nordson Corporation
All rights reserved
108 236B
Issued 1/97
Manual 4-26
2. Relieve all UNICARB system pressures as described below:
a. Press the STOP key to begin the shutdown procedure.
WARNING: Always turn OFF the power to the heaters and
allow them to cool before shutting down the circulating pump.
Failure to do so could result in a fire or an explosion from the
overheated coating materials.
b. Turn OFF the power to the heaters (if used with your system). Do
not turn off the circulating pump until the material in the system
has cooled.
c. Reduce the pump air supply pressure to zero and shut OFF the
system air supply.
d. Shut OFF the CO
2
booster pump, if used.
e. Close the outlet and inlet manifold ball valves.
f.
Disconnect and lock out all electrical power to the system.
3. Remove the coating material/CO
2
hose(s) from the gun.
4. See Figure 3. Remove the connector(s) (1) from the extension (2).
0426003A
1
2
Fig. 3 Material fittings removal
1. Connector
2. Extension
Handgun Disassembly
(contd)