1
Applicators PatternCoat
13
P/N 7135308_08
E
2014 Nordson Corporation
PatternCoat
Pneumatic Connection
Connecting Control Air
The applicator may only be connected to pressure controlled and
conditioned compressed air.
The quality of the compressed air must be at least class 2 as stipulated by
ISO 8573-1. This means:
S
Max. particle size 1
m
m
S
Max. particle density 1 mg/m
3
S
Max. pressure dewpoint -40 °C / -40 °F
S
Max. oil concentration 0.1 mg/m
3
.
1. Connect a controllable air supply to the control air fitting (1).
2. Set control air pressure to approx. 4 to 6 bar (0.4 to 0.6 MPa /
58 to 87 psi). The exact pressure must be determined for each
application.
Operating with Lubricated Compressed Air
The applicators / control modules can also be operated with lubricated
compressed air.
NOTE:
Once the air has been lubricated, it must always be lubricated; the
lubricated compressed air will wash out the original lubricant on the solenoid
valves and the control modules. Nordson recommends:
Oil
P/N
Klüber Unisilkon TK002/50
316578