1
2
3
14
Applicators PatternCoat
P/N 7135308_08
E
2014 Nordson Corporation
PatternCoat
Connecting Heated Hose
WARNING:
Hot! Risk of burns. Wear heat‐protective gloves.
Using Second Open‐end Wrench
Use a second open‐end wrench when connecting and disconnecting the
heated hose. This prevents the unit's hose connection from turning.
Connecting
If cold material can be found in the hose connection, these components (1, 2)
must be heated until the material softens (approx. 80 °C, 176 °F).
1. First connect the hose (3) electrically to the unit. For more than one hose:
Every hose connection is allocated to a corresponding receptacle. Do not
mistakenly exchange!
2. Heat the system and hose to approx. 80 °C (176 °F).
3. Screw on heated hose.
NOTE:
Close unused hose connections with Nordson port plugs.
Disconnecting
WARNING:
System and material pressurized. Relieve system pressure
before disconnecting heated hoses. Failure to observe can result in serious
burns.
WARNING:
Hot! Risk of burns. Wear safety goggles and heat‐protective
gloves.
1. Turn off material supply.
2. Place a container under the nozzle(s) of the applicator.
3. Activate the solenoid valves electrically or manually. Repeat this
procedure until no more adhesive flows out.
4. Properly dispose of material according to local regulations.