Operation
4-6
Part 1074166-02
E
2018 Nordson Corporation
Remotely Operated Units
NOTE:
The system can be wired to initiate
lamphead start from either the process machine or
from the UV power supply control panel.
Table 4-4 Startup Procedures for Units Operated Remotely
Step
Single Unit and Units Networked to a Master Unit Operated Remotely
1
Switch the electrical disconnect enclosure to ON.
2
Turn the main power switch on the front of the power supply unit to the on position.
3
Make sure that all interlocked access doors are closed and that the exhaust fan is running.
If external interlocks are wired and open, the Interlock/E-stop fault LED will light.
4
On the NETWORK selector, press Remote.
NOTE:
For networked remote units, press Remote at each NETWORK selector.
6
Lamphead with external blower
: Enable the cooling fan by either an external/remote
switch or the set of contacts from the power supply. If the exhaust fan is wired to the
normally open set of contacts on the power supply they will close when the lamphead is put
in Standby or Lamp On mode. Refer to Table 3 for external blower connection.
Lamphead with internal blower
: The blower will be controlled by the power supply.
If there is insufficient pressure (less than 2.5 in. W.C. static pressure) there will be a system
fault and the Air Pressure fault LED will appear in the display. (Check for proper pressure
with the appropriate instrumentation.)
7
There are many ways that the system can be configured to operate Remotely. By utilizing
the power supply I/O the UV system can be controlled from a simple panel or fully
automated to work in concert with a complete process. Contact a Nordson UV Curing
representative for details.
Summary of Contents for MPS306F
Page 4: ...Table of Contents ii Part 1074166 02 E 2018 Nordson Corporation...
Page 12: ...Safety 1 8 Part 1074166 02 E 2018 Nordson Corporation...
Page 16: ...Description 2 4 Part 1074166 02 E 2018 Nordson Corporation...
Page 40: ...Operation 4 8 Part 1074166 02 E 2018 Nordson Corporation...
Page 44: ...Maintenance and Repair 5 4 Part 1074166 02 E 2018 Nordson Corporation...
Page 48: ...Troubleshooting 6 4 Part 1074166 02 E 2018 Nordson Corporation...
Page 56: ...Specifications 8 4 Part 1074166 02 E 2018 Nordson Corporation Figure 8 2 IO Wiring...