Network Connections
NOTE:
Equipment must be connected in
accordance with the NEC and local wiring codes.
The power supply can be configured to form a
network of up to 16 systems. The entire network
can be operated either from the master control unit
front panel or from a remote source.
Network Connectors IN1 and
OUT1
Refer to Table 3-3 and Figure 3-6. Use the IN1 and
OUT1 connectors (1) (shielded RJ45) to connect
multiple units in a Master/Remote fashion. The
connection cable is commercially available and
should have a rating of CAT3 or higher. Repeat
this for each unit.
Table 3-3 IN1 and OUT1 Network Connectors
Cable
From
To
Length (ft)
Part
Network
OUT1 connector
of a unit
IN1 connector of
the next unit
6
775031