Control Board Dip Switches
There are two sets of dip switches (SW1 and SW3)
that need to be set on the main board. Tables 3-8
and 3-13 provide an explanation of each switch.
NOTE:
Switches 5 and 6 were added to control
boards manufactured after 2002.
SW1 Control Board Dip Switches
OPEN
DISPL
OR LED
REM CFG
FR
T PNL LOCK
RF DET
FAUL
T
REM ANALG
Figure 3-14 SW1 Dip Switch Configurations
Table 3-8 SW1 Control Board Dip Switches
Dip
Switch
Description
Function
1
Closed/On = Remote analog On
Open/Off = Remote analog Off
Configures the remote adjustable power input to on
or off. (TB2)
2
Closed/On = Fault individual units
Open/Off = Fault all units
Configures the power supply (standalone or
networked system) to shut down the individual lamp
or the entire network in the event of a fault.
3
Closed/On = RF Detector is used
Open/Off = RF Detector is not used
Configures the power supply unit to be operated
with or without an RF detector. Standalone systems
or master units cannot operate without an RF
detector.
An RF detector can be installed at each power
supply when necessary.
Networked systems are typically configured for the
master unit to have one RF detector while its
remote units (up to 16 units) do not.
NOTE:
Up to 16 units can be networked and
operate with one RF detector but it is recommended
that every six units have one RF detector.
4
Closed/On = Front panel controls Off
Open/Off= Front panel controls On
Configures the front panel of an individual power
supply to be enabled or disabled. When disabled,
all operational functions must be controlled by the
inputs or the network master.
5
Closed/On = Front Panel configuration
On
Open/Off = Front Panel configuration
Off
Allows power supply configuration to be completed
at the front panel.
6
Closed/On = Front Panel Digital display
Open/Off = Front Panel has LEDs only
Configures the control board for an LED only front
panel or a number display on the front panel.
Summary of Contents for MPS306F
Page 4: ...Table of Contents ii Part 1074166 02 E 2018 Nordson Corporation...
Page 12: ...Safety 1 8 Part 1074166 02 E 2018 Nordson Corporation...
Page 16: ...Description 2 4 Part 1074166 02 E 2018 Nordson Corporation...
Page 40: ...Operation 4 8 Part 1074166 02 E 2018 Nordson Corporation...
Page 44: ...Maintenance and Repair 5 4 Part 1074166 02 E 2018 Nordson Corporation...
Page 48: ...Troubleshooting 6 4 Part 1074166 02 E 2018 Nordson Corporation...
Page 56: ...Specifications 8 4 Part 1074166 02 E 2018 Nordson Corporation Figure 8 2 IO Wiring...