MEG® II Airless Spray Guns with 10 ft Cable
© 2021 Nordson Corporation
Installation
WARNING:
Allow only qualified personnel to perform the following tasks. Follow the
safety instructions in this document and all other related documentation.
WARNING:
The purchaser should make the manufacturer aware of any external effects
or aggressive substances that the equipment may be exposed to.
Mounting
See Figure 2.
Mount the MEG II gun on the mounting plate, using the two holes in the manifold base.
• If you are replacing an A10A, A14A, or A20A spray gun, remove it and use the two
socket head screws (2) shipped with the MEG II gun to secure it to the existing
mounting plate.
• If your system does not use any of these spray guns, refer to
Specifications
Fluid Connections
NOTE:
An approved pressure relief device set at 1300 psi (90 bar) must be installed in
the system fluid supply line. The fluid hoses must have a minimum burst pressure of 3000
psi (207 bar).
See Figure 2. Connect the fluid inlet and outlet hoses to the fluid fittings (7). Either fitting
may be used for the inlet. The fittings are 1/2-20 37° JIC.
1
2
3
4
5
6
7
8
9
10
Figure 2
MEG II Gun Components (Top View)
1. Electrical conduit
2. Socket head screws
3. Gun
4. Seat O-ring
5. Nozzle
6. Nozzle nut
7. CO plate plug and O-ring
8. Pressure Transducer plugs and
O-rings
9. Ground cable and clamp
10. Fluid Fittings