External Interlock Timer Setting (Optional)
The External Interlock timer function, if enabled in the configuration screen,
starts when a run signal is received from the customer line. If the motion
sensor does not detect motion before the timer expires, the alarm relay will
change state and activate a customer-supplied external alarm. The timer
setting is dependent on line speed.
Press the EXTERNAL INTL TIMER setting display area. When the pop-up
keypad appears, enter the new external interlock timer value and press
Enter on the keypad.
NOTE:
The motion sensitivity setting is used for motion signal tuning.
Figure 20
Ramp/Motion Setup Screen