Nordson EcoDry
r
Series Induction Dryers with Touch Screen Controls
21
Part 1601306
−
02
E
2014 Nordson Corporation
Operator Interface
The dryer is controlled by the use of Power On/OFF/E-Stop pushbuttons,
and a touchscreen operator interface system for dryer operations.
Figure 14 Automatic Screen
1. Press the POWER button on the Operator Control panel.
2. After the Nordson Splash screen appears, the Automatic screen
appears by default.
3. The control system will stay in automatic control while navigating
through the menus. The system will run in the Manual mode only when
the Manual screen is displayed.
4. All system settings are made from the touchscreen controller. The
system screens are:
S
NAVIGATION menu
S
AUTOMATIC
S
MANUAL
S
TEMP SETUP
−
display and change temperature related settings
S
PID
−
display and change PID settings
S
RAMP/MOTION
S
OFFSET/LIMITS
S
FAULT PAGE
S
CONFIGURATION
S
PLC I/O
−
displays the status of all system inputs and outputs