Temperature Menu
Command
Description
Command Format
Sample with Output
Set Units of
Temperature
Sets the temperature units for the
controller to Celsius or Fahrenheit
Host Format: xstmp
0stmp Degrees Celsius
1stmp Degrees Fahrenheit
0stmp [Enter]
Temperature Unit = C
1stmp [Enter]
Temperature Unit = F
Set Heater
Channel 1
Mode
Sets the mode of operation for heater 1 Host Format: xhtr1
0htr1
Disable the Channel
1htr1
Enable the Channel
2htr1
Reads back the status ON/OFF
0htr1 [Enter]
Heater Channel: 1 OFF
1htr1 [Enter]
Heater Channel: 1 ON
2htr1 [Enter]
Heater Channel: 1 ON
Set Heater
Channel 2
Mode
Sets the mode of operation for heater 2 Host Format: xhtr2
0htr2
Disable the channel
1htr2
Enable the channel
2htr2
Reads back the status ON/OFF
0htr2 [Enter]
Heater Channel: 2 OFF
1htr2 [Enter]
Heater Channel: 2 ON
2htr2 [Enter]
Heater Channel: 2 ON
Set Heater
Channel 1
Temperature
Sets the heater temperature for
heater 1
Host Format: DDDsht1
Where DDD is the desired temperature in
degrees Celsius or Fahrenheit
070sht1 [Enter]
Set Temperature = 70 °C
Set Heater
Channel 2
Temperature
Sets the heater temperature for
heater 2
Host Format: DDDsht2
Where DDD is the desired temperature in
degrees Celsius or Fahrenheit
080sht2 [Enter]
Set Temperature = 80 °C
Heater
Channel 1
Feedback
Returns the current settings for
heater 1
Host Format: rht1
rht1 [Enter]
MEM = 00
MODE = ON
SET = 32F
ACT = ---F
Heater
Channel 2
Feedback
Returns the current settings for
heater 2
Host Format: rht2
rht2 [Enter]
MEM = 00
MODE = ON
SET = 27F
ACT = ---F
Appendix B, RS-232C Connection Technical
Information (continued)
ValveMate 9000 Controller
71
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.