Connect Wiring
Connect a Dispense Valve Initiate Signal
Use either of the following methods to connect a dispense valve
initiate signal:
• VI1, VI2 Terminals
Use the supplied 16-position plug to
connect a 5–24 VDC initiate signal to
terminals VI1+ and VI2+ on the I/O
connection (refer to “Connect General
Purpose Inputs / Outputs”).
Connect Driver Outputs
Use the supplied 4-position plug to connect each driver output signal
to the solenoid valves for dispense valves 1 and 2.
The controller provides two driver outputs. Each output is 24 W,
5–24 VDC.
5–24 VDC
VI1+
VI1-
DRV1-
DRV1+
• Foot Pedal
Connect the optional foot
pedal (P/N 7014865) to the
foot pedal switch connection.
NOTE:
The foot pedal initiate signal is de-bounced for
a period of 20 ms. To disable the de-bounce on the foot
pedal signal, press the 5 key during power up or use the
serial command through a serial cable (RS-232C).
P/N 7014865