69
Technical parameters for solid fuel local space heaters
Model identifier(s):
Salzburg L
Indirect heating functionality:
no
Direct heat output:
2
(kW)
Fuel
Preferred fuel (only one):
Other suitable fuel(s):
Wood logs with moisture content ≤ 25 %
yes
no
Compressed wood with moisture content < 12 %
no
no
Other woody biomass
no
no
Non-woody biomass
no
no
Anthracite and dry steam coal
no
no
Hard coke
no
no
Low temperature coke
no
no
Bituminous coal
no
no
Lignite briquettes
no
no
Peat briquettes
no
no
Blended fossil fuel briquettes
no
no
Other fossil fuel
no
no
Blended biomass and fossil fuel briquettes
no
no
Other blend of biomass and solid fuel
no
no
Characteristics when operating with the preferred fuel
Seasonal space heating energy efficiency
η
s
[%]:
90
Energy Efficiency Index (EEI):
121,5
Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Heat output
Useful efficiency (NCV as received)
Nominal heat output
P
nom
2,0
kW
Useful efficiency at nominal
heat output
η
th,nom
90
%
Auxiliary electricity consumption
Type of heat output/room temperature control
(select one)
At nominal heat output
el
max
kW
single stage heat output, no room
temperature control
no
At minimum heat output
el
min
kW
two or more manual stages, no room
temperature control
yes
In standby mode
el
SB
kW
with mechanic thermostat room temperature
control
no
with electronic room temperature control
no
with electronic room temperature control plus
day timer
no
with electronic room temperature control plus
week timer
no
Other control options (multiple selections possible)
room temperature control, with presence
detection
no
room temperature control, with open window
detection
no
with distance control option
no
Permanent pilot flame power requirement
Pilot flame power requirement (if applicable)
P
pilot
kW
Contact details
Name and address of the supplier:
Nordpeis AS, Gjellebekkstubben 11, N-3420 LIERSKOGEN, Norway
Summary of Contents for PN-SAL01-300
Page 32: ...32 FIG 4 A B CO SAL01 02A CO SAL01 010 CO SAL01 010 1 A 1 B 2 A PI SAL01 010 PI SAL01 010 2 B...
Page 34: ...34 PI SAL01 04A PI SAL01 04B FIG 6 PI SAL01 030 FIG 5...
Page 36: ...36 FIG 8 A CO SAL01 020 CO SAL01 020 FIG 8 B CO SAL01 020 x4 A cryl x4 A cryl...
Page 47: ...47 Salzburg L Convection Salzburg L Convection 1 extension FIG 24 a FIG 24 b...
Page 51: ...51 8 mm FIG 30 A c r y l Acryl...
Page 52: ...52 FIG 31 IS SAL02 040 FIG 32 CO SAL01 060 22 SAL01 180 x 2...
Page 58: ...58 FIG 38d FIG 38c 10x6 LA SAL01 060...
Page 59: ...59 FIG 40 FIG 39 LA SAL01 070...
Page 60: ...60 FIG 41 FIG 42 LA SAL01 080 LA SAL01 090...
Page 61: ...61 FIG 44 FIG 43 180 20 Q27FL 010 22 SAL01 170 22 SAL01 160 A cryl...
Page 62: ...62 FIG 45 1 1 2 2...
Page 66: ...66 FIG 52 Salzburg L Convection 1 2 FIG Z A cryl A c r y l...