Some advice in case of combustion problems

Error

Explanation

Solution

No draught

The chimney is blocked

Contact a chimney sweeper / dealer for more information or clean 

the flue, smoke baffle and burn chamber.

The flue is sooty or there is accumulated soot on the 

smoke baffle
The smoke baffle is wrongly positioned

Verify the assembly of the smoke baffle - see assembly instructions.

The stove 

release smoke 

when lighting 

the fire and 

during combus

-

tion

Downdraught in the room caused by no draught, that the 

house is too “air tight”.

Light the fire with an open window. If this helps, more/bigger vents 

must be installed in the room.

Downdraught in the room – caused by extractor and/or 

central ventilation system that pulls too much air out of 

the room.

Turn off/regulate extractor and/or other ventilation. If this helps, 

more vents must be installed.

The flues from two fireplaces/stoves are connected to 

the same chimney at the same height.

One flue must be repositioned. The height difference of the two flue 

pipes must be of at least 30 cm. 

The flue is in a declining position from the smoke dome 

to the chimney.

The flue must be moved so that there is an inclination of at least 

10º from smoke dome to chimney. Possibly install a smoke suction 

device*.

The flue is too far into the chimney.

The flue must be reconnected so that it does not enter into the 

chimney but ends 5 mm before the chimney inner wall. Possibly 

install a smoke suction device*.

Soot hatch in the basement or attic that is open and thus 

creating a false draught.

Soot hatches must always be closed. Hatches that are not tight or 

are defected must be changed.

Damper/top draught vents or doors on fireplaces that are 

not in use are open and create a false draught.

Close damper, doors and top draught vents on fireplaces that are 

not in use.

An open hole in the chimney after that a fireplace has 

been removed, thus creating a false draught.

Holes must be completely sealed off with masonry.

Defect masonry in the chimney, e.g. it is not airtight 

around the flue pipe entry and/or broken partition inside 

the chimney creating a false draught.

Seal and plaster all cracks and sites that are not tight.

The cross-section in the chimney is too large which 

results in no or very low draught.

The chimney must be refitted, possibly install a smoke suction 

device*.

The cross-section in the chimney is too small and the 

chimney cannot carry out all the smoke.

Change to a smaller fireplace or build new chimney with a larger 

cross section. Possibly install a smoke suction device*.

The chimney is too low and hence a poor draught.

Increase the height of the chimney and/or install a chimney cap/

smoke suction device*.

The stove 

releases smoke 

inside when 

it is windy 

outside.

The chimney is too low in relationship to the surrounding 

terrain, buildings, trees etc.

Increase the height of the chimney and/or install a chimney cap/

smoke suction device*.

Turbulence around the chimney due to the roof being 

too flat.

Increase the height of the chimney and/or install a chimney cap/

smoke suction device*.

The stove does 

not heat suf-

ficiently.

The combustion receives too much oxygen due to a 

leakage under the lower border of the stove or too strong 

chimney draught. Difficult to regulate the combustion and 

the wood burn up too quickly.

Any possible leakage must be sealed off. A draught regulator or 

possibly a damper can reduce the chimney draught. NB! A leakage 

of only 5 cm2 is enough for 30% of the heated air to disappear.

Too much 

draught

The smoke buffer is wrongly positioned.

Verify the positioning of the smoke buffer – see assembly instruc

-

tions.

In case of using oven-dried wood, this requires less air 

supply than when using normal wood.

Turn down the air supply.

The gaskets around the door are worn and totally flat.

Replace the gaskets, contact your dealer.

The chimney is too large.

Contact chimneysweeper or other professional for more details.

The glass is 

sooty

The wood is too wet.

Only use dry wood with a humidity of maximum 20%.

The air vent control is closed too tightly.

Open the air vent control to add air to the combustion. When new 

wood logs are inserted all vent controls should be completely 

opened or the door slightly opened until the flames have a good 

take on the wood.

White glass

Bad combustion (the temperature is too low)

Follow the guidelines in this user guide for correct combustion.

Using wrong material for combustion (such as: painted 

or impregnated wood, plastic laminate, plywood etc)

Ensure to use only dry and clean wood.

Smoke is relea-

sed when the 

door is opened

A levelling out of pressure occurs in the burn chamber.

Open the air vent control for about 1 min before opening the door 

– avoid opening the door too quickly.

The door is opened when there is a fire in the burn 

chamber.

Open the door carefully and/or only when there is hot ember.

White smoke

The combustion temperature is too low.

Increase the air supply.

The wood is humid and contains water damp.

Ensure to use only dry and clean wood.

Black or grey/

black smoke

Insufficient combustion.

Increase the air supply.

Summary of Contents for Havanna

Page 1: ...Art no FP HAV00 1X0 Last updated 06 07 2018 Test report no RRF 40 12 2937 Havanna with insert GB User manual 2 DE Montageanleitung 9 FR Manuel d installation 20...

Page 2: ...ase carefully read the user manual and follow the instructions 3 Integrated or defined convection openings may never be reduced or partially obstructed This may lead to overheating which again can cau...

Page 3: ...water The joint can be painted after a couple of days Painting When the fireplace has been filled sanded and the glued joints are dry the fireplace is ready to be painted Use only breathable paint acr...

Page 4: ...e relative to the fireplace as the chimney does not heat up well enough In such cases you may want to contact professional for evaluation of possible measures Draught that is too strong can be control...

Page 5: ...ireplace is assembled and all instructions have been observed a fire can be lit Take care when inserting logs into the burn chamber in order not to damage the Thermotte plates Please note that there m...

Page 6: ...ww nordpeis com Warning Use replacement parts recommended only by the Manufacturer IMPORTANT Always remember to open the air vent control and the door when new wood logs are inserted into a hot burn c...

Page 7: ...air vent and have the door slightly ajar in order for the flames to establish properly on the wood Note that the air supply for the combustion also can be too large and cause an uncontrollable fire t...

Page 8: ...smaller fireplace or build new chimney with a larger cross section Possibly install a smoke suction device The chimney is too low and hence a poor draught Increase the height of the chimney and or ins...

Page 9: ...gen 3 Integrierte oder anders hergestellte Konvektions ff nungen d rfen niemals reduziert oder teilweise ber deckt werden Dies kann zu einer berhitzung f hren was wiederum Hausbr nde oder schwere Sch...

Page 10: ...peis AS haftet nicht f r unsachgem e Installation Gewicht Der Hausbesitzer muss sich vergewissern dass der Boden das Gesamtgewicht des Kamines tragen kann Wenn das Produkt auf einem flie end verlegten...

Page 11: ...ubereiten Auch bei lteren Konstruktionen empfehlen wir das Zuluft Kit Ungen gende Zuluft kann Unterdruck verursachen eine effiziente Verbrennung und optimale Nutzung des Holzes verhindern und zu den b...

Page 12: ...eiden beachten Sie dass die Oberfl che beim Betrieb hei werden kann Daher ist besondere Vorsicht geboten damit keine Hautverbrennungen verursacht werden 4 Sicherheitsabstand Vergewissern Sie sich dass...

Page 13: ...e einen nicht brennbaren hitzeunempfindlichen Beh lter um die Asche zu entfernen Wir empfehlen eine d nne Schicht Asche in der Brennkammer zu belassen da dies durch die isolierende Wirkung die n chste...

Page 14: ...cht Sie k nnen dauerhaften Schaden verursachen f r den kein Garantieanspruch besteht kann daher nicht mit dem Altglas entsorgt werden Bei gemeinsamer Entsorgung mit Altglas w rde es die Wiedergewinnun...

Page 15: ...nungsluft zustr men Die Grundfl che des Aufstellraumes mu so gestaltet und so gro sein da die offenen Kamine ordnungsgem betrieben werden k nnen Offene Kamine d rfen nicht aufgestellt werden in Treppe...

Page 16: ...luft innerhalb eines Abstandes von 50 cm bis zu einer H he von 50 cm ber den Austrittsstellen keine Bauteile mit brennbaren Baustoffen keine derartigen Verkleidungen und keine Einbaum bel befinden Tra...

Page 17: ...endet werden Die Verfeuerung von Abf llen und insbesondere Kunststoff ist laut Bundesimmissionsschutzgesetz ver boten Dar ber hinaus schadet dies der Feuerst tte und dem Schornstein Lufttrockenes Sche...

Page 18: ...zt ren von Feuerst t ten die nicht in Betrieb sind stehen offen und verurs achen falsche Druckverh ltnisse Ofenklappe Feuerraumt r und Regler von Feuerst tten die nicht in Betrieb sind schlie en Offen...

Page 19: ...euern in der Montagean leitung lesen Falsches Befeuern mit Abfallholz lackiertem oder impr gniertem Holz Plastik sonstigem Abfall Ausschlie lich trockenes reines Spaltholz verwenden Bei ffnen der Feue...

Page 20: ...res de convection int gr es ou d sign es ne doivent jamais tre totalement ou partiellement obstru es Cela peut conduire une surchauffe ce qui peut son tour provoquer un incendie dans la maison ou des...

Page 21: ...se un mur inflammable Poids Le propri taire du domicile doit s assurer que la dalle comme le type de plancher peuvent supporter le poids de l appareil et sa chemin e Lorsque le produit est install sur...

Page 22: ...tible La dimension de la plaque de sol doit etre conforme aux r gles en vigueur dans le pays Cotes et dimensions L illustration montre la distance approximative entre le sol et le centre du trou pour...

Page 23: ...tilisez ult rieurement le po le et la chemin e peuvent surchauffer Quand il y a une couche rougeoyante de charbon rajouter quelques buches En ins rant des nouvelles buches rappelez vous de tirer la br...

Page 24: ...es ann es La date de remplacement d pend de l utilisation qui est faite du produit Nordpeis garantit ces pi ces un an Une fois la garantie pass e vous pouvez acheter des pi ces de rechange Lors du d m...

Page 25: ...ui peuvent conduire des temp ratures trop lev es Attention Assurez vous que le po le n est pas surchauff La garantie ne couvre aucun d gats en cas de surchauffe 8 Garantie Pour une description d taill...

Page 26: ...ntuellement installer un dispositif d aspiration de fum e Le conduit d evacuation des fum es est trop bas et par cons quent le tirage faible Augmenter la hauteur de la chemin e et ou installez un disp...

Page 27: ...2005 1330 855 FIG 1 mm The connection height is based on the use of 2x45 angled pipes Die Anschlu h he ergibt sich aus der Verwendung eines 2x45 Winkelrohr La hauteur de connection est li e l utilisat...

Page 28: ...wall Mur parefeu Hitzenschutzwand Brennbart materiale Br ndbart materiale Br nnbart material Tulenarka materiaali Combustible material Mati res combustibles Brennbarem Material 100 50 100 50 1060 1060...

Page 29: ...29 A B C D E F FIG 6 FIG 5 FIG 3 FIG 4 30 mm x3 CO HAV00 010 B...

Page 30: ...30 4 FIG 8 FIG 10 FIG 7 FIG 9 175 20 175 20 Acryl 3 mm 8 mm CO HAV00 080 CO HAV00 030 IN 0N31V 000 CO HAV00 040...

Page 31: ...31 FIG 13 FIG 11 FIG 12 Acryl CO HAV00 050 CO HAV00 070...

Page 32: ...32 FIG 14 FIG 15 FIG 16 CO HAV00 060 CO HAV00 020 CO HAV00 070 FIG 14b Acryl Acryl 1 2 FIG Z...

Page 33: ...33 FIG 17 A B C 3 mm...

Page 34: ...34 6 Havanna Air 1 Havanna Air 2 155 490 240 240 98...

Page 35: ...35 Havanna Air 3 10...

Page 36: ...ut Useful efficiency NCV as received Nominal heat output Pnom 6 kW Useful efficiency at nominal heat output th nom 80 Auxiliary electricity consumption Type of heat output room temperature control sel...

Page 37: ...6 0 A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A A Nordpeis AS Nordpeis S 31A 37...

Page 38: ...PLASSERING AV SERIENUMMER POSITION OF THE SERIAL NUMBER PLACERING AV SERIENUMMER SARJANUMERON SIJAINTI 38...

Page 39: ...39...

Page 40: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...

Reviews: