3. Part : INSTALLATION AND PREPARATIONS FOR USE
8
•
.
•
.
•
.
3.3 Adjustment of feet
.
3.4 Gas connection
Pay attention not to place it near the refrigerator, there must be no
flammable or inflammable materials such as curtain, waterproof cloth, etc.
that will begin to burn quickly
It is required that there must be least a 2cm blank space around the oven for
air circulation
If the kitchen furniture are higher than the hob plate of the oven, it must be
at least 10cm away from the oven's side.
The minimum heights from the oven's pan and wall cupboards and cooker
hoods with fan over the oven, are shown as above. Thus, the cooker hood must
be at minimum 65cm height from the cooker pan. If there is no cooker hood,
this height must not be less than 70cm.
Your oven stands on 4 adjustable feet. When the oven is placed where it will be
used, check if the oven is balanced. If it is not balanced, you can make the
adjustment by turning the feet clockwise if required. It is possible to raise the
appliance maximum 30mm by the feet. If the feet are adjusted appropriately, it
is required not to move the appliance by dragging, it should be moved by lifting
it up
The connection of the appliance should be performed in accordance with local
and international standards and regulations applicable. You can find the
information related to appropriate gas types and appropriate gas injectors on
technical data table. If the pressure of used gas is different than these values
stated of the or not stable in your area, it may be required to assemble an
available pressure regulator on the gas inlet. It is certainly required to contact
to the authorized service to make these adjustments.
The points that must be checked during flexible hose assembly
If the gas connection is made by a flexible hose that is fixed on the gas inlet of
appliance, it must be fixed by a pipe collar as well. Connect your appliance with
a short and durable hose that is as close as possible to the gas source. The
hose's permitted maximum length is 1.5m. The hose that brings gas to the
appliance must be changed once a year for your security.
The hose must be kept clear from areas that may heat up to temperatures in
0
excess of 50 C. The hose must not be ruptured, bent or folded. The hose must
be kept clear of sharp corners, moving things, and should not be defective.
Before assembly, it must be checked whether there is any production defect.