faults DurinG operation
problem
possible causes
smoke leak
- check return temperature (min. 60 °c)
- check flue draught (15 Pa)
- check room air inlet supply
- check wood moisture (not above 20 % and not below 12 %)
- logs too large
- check smoke channel development and cleanliness
- set fan power based on fireplace draught
The boiler does not deliver enough power
- check return temperature (min. 60 °c)
- check flue draught (15 Pa)
- check wood moisture (not above 20 % and not below 12 %)
- logs too large
- check wood load
discharge smoke temperature too high
- check flue draught
- adjust secondary air
- Insert fuel correctly into the boiler
hot water temperature too high
- check system sizing
- check circulator dimensions and operation
- check return temperature (min. 60 °c)
condensation in boiler
- check return temperature (min. 60 °c)
- check flue draught
- check room air inlet supply
- check wood moisture (not above 20 % and not below 12 %)
- set fan power based on fireplace draught
The heating system does not heat
- check system sizing
- check the heat demand
- check circulator dimensions and operation
- check return temperature (min. 60 °c)
The smoke fan does not work
- check the condenser
- check smoke fan motor
- check smoke fan impeller
- check the possible triggering of the safety thermostat and reset it
if necessary.