25°C
20 °C
0 %
ENGLISH
scrollinG throuGh the menu
Temp.
WaTer
Temp.
smoke
air
Press the
menu
key
1) IgnITIon (on/off)
2) manual (on/off)
3) boIler PumP TemPeraTure (seT degrees)
4) acousTIc alarm (on/off)
5) language (selecT language)
6) buffer Tank on (on/off)
7) manufacTurer’s seTTIngs (yes/no)
8) chImney flue TyPe:
a) sWITch on (on/off)
b) smoke rPm (0-100%)
c) WorkIng TIme (.....mInuTes)
use the arrow keys
to move
from one item to another
confirm with the
“flashing” menu item
go back to the home
page by pressing exit
menu item
Description of work mode
heating
The boiler goes into heating mode
and runs the fan continuously up to 100%.
duration of heating time 30 min.
manual operation
(components test)
1) fan speed test (0 - 100%)
2) fan test (on/off)
3) boiler circuit pump test (on/off)
4) Test alarm signal (on/off)
Pump (boiler circuit pump)
Indication of switch-on temperature
of the boiler circuit pump 20 - 75°c,
factory setting 65°c, hysteresis 2°c,
switch-off temperature depending on the
buffer probe
alarm tone
activates or deactivates the alarm signal.
The alarm signal is active in the factory setting.
language
language setting (german,
english, french, russian, Polish, danish, swedish, slovenian,
Italian, spanish)
buffer sensor
If no buffer sensor is active, the boiler circuit pump
is switched on and off according to the boiler temperature.
If the buffer probe is active, the boiler circuit pump is
controlled according to the temperature difference between the boiler
and the buffer tank (buffer tank management).
factory setting
restore factory settings.
chimney sweep mode
activation of chimney sweep mode
setting of the fan speed
and operating temperature
factory setting 70% and 45 min.
36
36