CAlCulATIoN of ThE ThERMAl powER
There is not an absolute rule for calculating the correct necessary power. This power is given according to the space to be heated, but it
depends also largely on the insulation. On an average, the calorific value necessary for a properly insulated room is
30 kcal/h per m
3
(for an
external temperature of 0°C).
given that
1 kw corresponds to 860 kcal/h
, it is possible to adopt a value of
35 w/m
3
.
Let’s suppose one wishes to heat a room of 150 m
3
(10 x 6 x 2.5 m) in an insulated apartment. In this case, it is necessary to have 150 m
3
x 35
w/m
3
= 5250 w or 5,25 kw. As main heating, a 8 kw device is therefore sufficient.
Approximate combustion value
Required quantity in relation to
1 kg of dry wood
fuel
unit
kcal/h
kw
Dry wood (15% humidity)
kg
3600
4.2
1,00
wet wood (50% humidity)
kg
1850
2.2
1,95
wood briquettes
kg
4000
5.0
0,84
Brown coal briquettes
kg
4800
5.6
0,75
Normal anthracite
kg
7700
8.9
0,47
Coke
kg
6780
7.9
0,53
Natural gas
m
3
7800
9.1
0,46
Naphtha
L
8500
9.9
0,42
Electricity
kw/h
860
1.0
4,19
RouTINE MAINTENANCE pERfoRMED by quAlIfIED TEChNICIANs
RouTINE MAINTENANCE MusT bE pERfoRMED AT lEAsT oNCE A yEAR.
USINg wOOD AS SOLID FUEL, ThE gENERATOR REqUIRES ANNUAL ROUTINE MAINTENANCE, whICh MUST BE PERFORMED By A
quAlIfIED TEChNICIAN, usINg oNly oRIgINAl spARE pARTs.
FAILURE TO COMPLy CAN jEOPARDISE ThE SAFETy OF ThE APPLIANCE AND MAkE ThE wARRANTy NULL AND VOID.
Respecting the frequencies of cleaning reserved for the user described in the use and maintenance manual, the generator is guaranteed
correct combustion over time, preventing any anomalies and/or malfunctioning that could require more interventions of the technician.
REqUESTS FOR ROUTINE MAINTENANCE ARE NOT CONTEMPLATED IN ThE PRODUCT wARRANTy.
gAsKETs
The gaskets guarantee the tightness of the product and its consequent good functioning.
ThEy MUST BE CONTROLLED PERIODICALLy. ThEy MUST BE REPLACED IMMEDIATELy IF ThEy ARE wORN OR DAMAgED.
ThESE OPERATIONS MUST BE CARRIED OUT By A qUALIFIED TEChNICIAN.
CoNNECTIoN To ThE fluE
VACUUM AND CLEAN ThE PIPE ThAT LEADS TO ThE FLUE yEARLy OR ANy TIME ThAT IT IS NECESSARy. IF ThERE ARE hORIZONTAL TRACTS,
ThE RESIDUE MUST BE REMOVED BEFORE IT CAN PREVENT ThE PASSAgE OF ThE FUMES.