Installation Basics
Sample Bill of Materials
FROM MARITIME GEOTHERMAL
• AHW/AH4P SERIES AIR HANDLER
• PLENUM HEATER __kW
• P/T PORTS AND HOSE ADAPTERS (2)
DUCTWORK
• OUTLET PLENUM ADAPTER W/ FLEXIBLE COLLAR
• RETURN AIR ADAPTER W/ FLEXIBLE COLLAR
• TRUNK DUCT W/ JOINERS
• 6” ROUND DUCT W/ADAPTERS
• ALUMINUM TAPE
• SHEET METAL SCREWS
PIPING
• PIPE (HYDRONIC LOOP & CONDENSATE DRAIN)
• PIPE FITTINGS
• ZONE VALVE or ZONE PUMP
• ANTIFREEZE (IF USED)
ELECTRICAL
• THERMOSTAT OR CONTROLLER
• SERVICE WIRE: 14-2 OR 12-2
• PLENUM HEATER SERVICE WIRE
• BREAKER
• PLENUM HEATER BREAKER
• THERMOSTAT WIRE 18-4 (OR 18-8 FOR MULTISPEED)
• THERMOSTAT WIRE 18-2 (PLENUM HEATER)
• FORK TERMINALS FOR TSTAT WIRE (10)
• CONDENSATE PUMP & HOSE (IF REQUIRED)
Unpacking the Unit
When the air handler reaches the site it should be
unpacked to determine if any damage has occurred during
shipment. Any visible damage should be noted on the carrier's
freight bill and a suitable claim filed at once.
The unit is well constructed and every effort has been
made to ensure that it arrives intact; but it is in the customer's
best interest to check the unit thoroughly when it arrives.
Unit Placement
Ducted air units should be centrally located in the building
with respect to the conditioned space. A heating, cooling, or
dehumidification system cannot be expected to produce have an
even effect throughout the building when it is located at one end
of the structure and the air is transmitted a long distance with
uninsulated metal ductwork.
The front (piping side) access panel should remain clear of
obstruction for a distance of
2 ft (0.7 m)
to facilitate servicing
and maintenance. Ensure the unit is level to eliminate any pos-
sible condensate draining issues.
Horizontal models come equipped with an air filter rack on
which all four sides are removable for changing air filter, while
vertical models come with an air filter rack which can be in-
stalled with the removable end on either side. Be careful not to
run piping in front of the filter rack access cover.
Note that since AHW units require an
external condensate
trap
(see
Piping
chapter), they can not easily be floor mounted.
They will instead need to be hung or placed on a low stand at
least
5.5” (14 cm)
higher than the floor.
Horizontal
units may be hung using threaded rod and an-
gle or channel iron bars underneath. Be sure the hanging sys-
tem is suitable for
2X
the weight of the unit.
AHW: Air Return & Outlet Orientation
On all
2-pipe
air handler models, the air return and outlet
are in a fixed orientation in relation to to ‘front’ of the unit (the
side where water pipes are located).
For
horizontal 2-pipe
models, the air returns to the back
side and is discharged to the right.
For
vertical 2-pipe
models, the air returns to the back side
and is discharged upwards.
See
Dimensions
section at the end of this manual.
AH4P: Air Return & Outlet Orientation
On all
4-pipe
air handler models, the air return and outlet
are in a fixed orientation in relation to to ‘front’ of the unit (the
side where water pipes are located).
For
horizontal 4-pipe
models, the air returns on the
left.
The blower position is field convertible in order to discharge air
to either the
right side
(default position) or
back
.
For
vertical 4-pipe
models, the air returns on the
left
side
and is discharged upwards.
See
Dimensions
section at the end of this manual.
Summary of Contents for AH4P Series
Page 10: ...5 Jul 2022 Page 10 002596MAN 01 ...
Page 26: ...5 Jul 2022 Page 26 002596MAN 01 Wiring Diagram 24VAC Airflow Control ...
Page 27: ...5 Jul 2022 Page 27 002596MAN 01 Wiring Diagram VSP models 0 10VDC Airflow Control ...
Page 28: ...5 Jul 2022 Page 28 002596MAN 01 Dimensions AHW 65 Horizontal Dimensions AHW 65 Vertical ...
Page 29: ...5 Jul 2022 Page 29 002596MAN 01 Dimensions AH4P 65 Horizontal Dimensions AH4P 65 Vertical ...