5-Jul-2022
Page 25
002596MAN-01
COOLING
METRIC
AHW/AH4P-65 Vertical
EAT
(
°F)
Airflow
(cfm)
Water
Flow
(gpm)
EWT =
40
°F
EWT =
45°
F
EWT =
50°
F
Water
Pressure
Drop
(psi)
Total
Capacity
(Btu/hr)
Sensible
Capacity
(Btu/hr)
LAT
(
°F)
LWT
(
°F)
Total
Capacity
(Btu/hr)
Sensible
Capacity
(Btu/hr)
LAT
(
°F)
LWT
(
°F)
Total
Capacity
(Btu/hr)
LAT
(
°F)
LWT
(
°F)
80.6
(46%
RH)
900
2
25,200
21,100
59
65
21,900
19,400
61
67
17,100
63
67
0.2
4
34,900
26,300
54
57
29,600
24,000
56
60
24,600
59
62
0.8
6
40,800
29,000
51
54
34,200
26,200
54
56
27,800
57
59
2.1
8
44,700
30,800
50
51
37,400
27,600
53
54
30,000
56
58
3.5
1200
2
27,500
23,800
63
68
24,100
21,800
64
69
18,800
66
69
0.2
4
39,100
31,200
57
60
33,600
28,800
59
62
28,400
61
64
0.9
6
46,500
34,800
54
55
39,400
31,800
57
58
32,400
59
61
2.1
8
51,800
37,200
52
53
43,500
33,700
55
56
35,300
58
59
3.5
1500
2
29,000
25,500
65
69
23,200
23,200
67
62
20,000
69
70
0.2
4
42,200
35,200
59
61
36,700
32,500
61
63
31,300
63
66
0.9
6
50,900
39,800
57
57
43,400
36,600
59
59
36,300
61
62
2.1
8
57,100
42,800
55
54
48,300
39,000
57
57
39,600
59
90
3.5
1900
2
27,900
27,900
67
68
24,600
24,600
69
70
21,200
71
71
0.2
4
45,600
39,400
62
63
39,900
36,300
63
65
32,000
65
66
0.9
6
55,500
45,500
59
58
47,800
42,000
61
61
40,500
62
64
2.1
8
62,900
49,300
57
56
53,400
45,200
59
58
44,500
61
61
3.5
2300
2
29,000
29,000
69
62
25,500
25,500
71
71
22,000
72
72
0.2
4
48,400
42,700
64
64
42,500
39,200
65
66
34,200
67
67
0.9
6
59,200
50,300
61
60
51,400
46,400
62
62
41,600
64
64
2.1
8
67,300
54,900
59
57
57,700
50,600
61
59
48,800
63
62
3.5
Sensible
Capacity
(Btu/hr)
17,100
21,900
23,500
24,500
18,800
26,200
28,800
30,300
20,000
29,500
33,300
35,300
21,200
32,000
38,200
41,100
22,000
34,200
41,600
46,000
EAT
(
°C)
Airflow
(L/s)
Water
Flow
(L/s)
EWT =
4
°C
EWT =
7°
C
EWT =
10°
C
Water
Pressure
Drop
(kPa)
Total
Capacity
(kW)
Sensible
Capacity
(kW)
LAT
(
°C)
LWT
(
°C)
Total
Capacity
(kW)
Sensible
Capacity
(kW)
LAT
(
°C)
LWT
(
°C)
Total
Capacity
(kW)
LAT
(
°C)
LWT
(
°C)
27
(46%
RH)
425
0.13
7.4
6.2
15.2 18.4
6.4
5.7
16.1 19.4
5.0
17.4 19.4
2
0.25
10.2
7.7
12.3 14.1
8.7
7.0
13.6 15.4
7.2
14.8 16.8
6
0.38
11.9
8.5
10.8 11.9
10.0
7.7
12.3 13.6
8.2
13.8 15.2
14
0.50
13.1
9.0
9.8 10.6
11.0
8.1
11.6 12.4
8.8
13.3 14.2
24
570
0.13
8.1
7.0
17.0 19.7
7.1
6.4
17.8 20.6
5.5
19.1 20.4
2
0.25
11.5
9.2
13.9 15.3
9.8
8.4
14.9 16.6
8.3
16.0 17.9
6
0.38
13.6
10.2 12.4 13.0
11.5
9.3
13.7 14.5
9.5
14.9 16.0
14
0.50
15.2
10.9 11.3 11.6
12.7
9.9
12.8 13.2
10.4
14.3 14.9
24
710
0.13
8.5
7.5
18.4 20.5
6.8
6.8
19.2 16.4
5.9
20.3 21.1
2
0.25
12.4
10.3 15.2 16.2
10.7
9.5
16.1 17.4
9.2
17.1 18.7
6
0.38
14.9
11.7 13.6 13.8
12.7
10.7
14.7 15.2
10.6
15.8 16.7
14
0.50
16.7
12.5 12.6 12.3
14.1
11.4
13.9 13.9
11.6
15.1 32.2
24
900
0.13
8.2
8.2
19.6 19.9
7.2
7.2
20.5 20.8
6.2
21.4 21.8
2
0.25
13.4
11.6 16.6 17.1
11.7
10.6
17.4 18.3
9.4
18.5 18.9
6
0.38
16.3
13.3 14.9 14.7
14.0
12.3
15.9 16.1
11.9
16.9 17.5
14
0.50
18.4
14.4 13.9 13.2
15.6
13.3
15.0 14.6
13.1
16.1 16.2
24
1100
0.13
8.5
8.5
20.7 16.9
7.5
7.5
21.4 21.4
6.4
22.2 22.2
2
0.25
14.2
12.5 17.6 17.9
12.5
11.5
18.4 19.0
10.0
19.5 19.5
6
0.38
17.3
14.7 16.0 15.4
15.1
13.6
16.8 16.7
12.2
17.9 17.7
14
0.50
19.7
16.1 14.9 13.8
16.9
14.8
15.9 15.2
14.3
16.9 16.8
24
Sensible
Capacity
(kW)
5.0
6.4
6.9
7.2
5.5
7.7
8.4
8.9
5.9
8.7
9.8
10.4
6.2
9.4
11.2
12.1
6.4
10.0
12.2
13.5
COOLING
EWT = Entering Water Temperature
LWT = Leaving Water Temperature
EAT = Entering Air Temperature (dry bulb)
LAT = Leaving Air Temperature (dry bulb)
Lines shaded GREY = No dehumidification;
operation not recommended
Performance Tables - Vertical Models
Summary of Contents for AH4P Series
Page 10: ...5 Jul 2022 Page 10 002596MAN 01 ...
Page 26: ...5 Jul 2022 Page 26 002596MAN 01 Wiring Diagram 24VAC Airflow Control ...
Page 27: ...5 Jul 2022 Page 27 002596MAN 01 Wiring Diagram VSP models 0 10VDC Airflow Control ...
Page 28: ...5 Jul 2022 Page 28 002596MAN 01 Dimensions AHW 65 Horizontal Dimensions AHW 65 Vertical ...
Page 29: ...5 Jul 2022 Page 29 002596MAN 01 Dimensions AH4P 65 Horizontal Dimensions AH4P 65 Vertical ...