TECHNICAL INFORMATION: main adjustment parameters.
TECHNICAL DOCUMENTATION INSERTED IN COUNTER
Each counter has a
yellow envelope placed inside near the serial number plate
. This envelope
contains all the required technical documentation, such as:
−
Use and maintenance manual;
−
Declaration of conformity;
−
Quality control sheet;
−
Test inspection certificate;
−
Counter wiring diagram;
−
Lighting system diagram;
−
Manual of controller installed on electric panel (only if foreseen);
−
Controller parameters map (only if present);
−
Various documentation such as: motorised night blind instructions, electronic valve instruc-
tions,... (only if present).
N.B.:
At times, other labels with additional instructions and/or recommendations are applied to some
surfaces of the counter.
Par.
DESCRIPTION
Adjustment
range
CLIO 2.0
Cl. L1
(
-
18/
-
20°C)
SET
Temperature control setting
LS÷US
-
21
HY
Differential
0,1÷25,5 °C
2
dtE
End defrost temp.
-
50,0÷110,0 °C
8
idF
Defrost cycles interval
1÷120 hours
24
MdF
Maximum defrost duration
0÷255 min
50