![Norcold N1090 Series Service Manual Download Page 7](http://html1.mh-extra.com/html/norcold/n1090-series/n1090-series_service-manual_1701066007.webp)
Refrigerator Service Manual / Manuel d'entretien du réfrigérateur / Manual de servicio del refrigerador
7
N1090 Models / Modèles N1090 / Modelos N1090
DIAGNOSTIC SYMPTOM CHART
LED Flash Codes
Possible
Symptoms
Possible Cause
Action to Take
One flash 1/4 seconds, pause, repeat.
BATTERY
cuts out
The voltage is outside the cut out setting.
Perform Test A. Refer to page
9.
Two 1/4 second flashes, pause, repeat.
FAN
cuts out
The fan electrical load exceeds more than 1.0 amp.
Perform Test B. Refer to page
10.
Three 1/4 second flashes, pause, repeat.
MOTOR
will not start
The rotor is blocked or the differential pressure in the
refrigeration system is too high ( >5 bar).
Perform Test C. Refer to page
11.
Not Applicable
MOTOR
will not run
• Blown fuse in DC circuit
• Undersized wiring to refrigerator, minimum #12
gauge wire required, refer to Installation Manual
• Partially discharged battery, voltage below 11.3
VDC at compressor module
• High resistance (voltage drop) in supply circuit
Perform Test J. Refer to page 18.
Four 1/4 second flashes, pause, repeat.
MOTOR
will not maintain minimum
speed
If the refrigeration system is too heavily loaded,
the motor can not maintain minimum speed (1850
rpm).
Perform Test D. Refer to page
12.
Five 1/4 second flashes, pause, repeat.
MOTOR
periodically cuts out
If the refrigeration system has been too heavily load-
ed or the ambient temperature is high, the electronic
unit will run too hot.
Perform Test E. Refer to page
13.
Not Applicable
NOT COOLING
not turning on
• Faulty
thermostat
• Power to control module
• Faulty wire from control module to compressor
• Faulty control module
• Faulty
Compressor
Perform Test F. Refer to page 14.
Not Applicable
NOT COOLING
Runs, but does not cool
properly
• Bad capillary tube position
• Faulty
thermostat
• Faulty control module
Perform Test I. Refer to page 17.
Not Applicable
NOT COOLING
compressor starts but shuts
off directly
Overheated due to high ambient temperature
Turn off refrigerator for one (1)
hour, vent the vehicle, change
refrigerator to day mode.
Not Applicable
NOT COOLING
compressor does not run
at all
• Battery voltage is too low.
Recharge the battery.
• Start delay of one (1) minute.
Wait one (1) minute.
• Overheated due to high ambient temperature.
Turn off refrigerator for one (1)
hour, vent the vehicle, change
refrigerator to day mode.
• Vehicle fuse has blown.
Check fuse rating, replace with
15A fuse.
Not Applicable
NOT COOLING
Ventilation openings are completely or partially
blocked.
Clean or remove the blockage
The door is not properly closed.
Close the door, make sure the
seals are in good condition.
There is more than 0.12 inch ice on evaporator
Defrost the refrigerator, make sure
the seals are in good condition.
Overheated due to high ambient temperature.
Turn off refrigerator for one (1)
hour, vent the vehicle, change
refrigerator to day mode.
Not Applicable
NOT COOLING
Compressor runs continu-
ously
Go to a Service Center.