Troubleshooting, cont’d.
Possible Cause:
■
Blown fuse in DC circuit
■
Undersized wiring to refrigerator,
minimum #12 gauge wire required,
refer to Installation Manual for rec-
ommended wire size
■
Partially discharged battery, volt-
age below 11.3 VDC at compressor
module
■
High resistance (voltage drop) in
supply circuit
Troubleshooting - Test J, Will Not Run On DC Power
Is wiring to refrigerator at least 12 AWG
(required)?
START
Replace fuse;
test unit.
Is voltage below 11.3 VDC at
compressor module?
Perform Diagnostic Prechecks.
Is the DC fuse intact?
No
Yes
Yes
ZĞĨĞƌƚŽ/ŶƐƚĂůůĂƟŽŶDĂŶƵĂůĨŽƌ
recommended wire size
.
No
ZĞĐŚĂƌŐĞŽƌƌĞƉůĂĐĞďĂƩĞƌLJ͖
test unit
.
Yes
No
Correct high resistance
;ǀŽůƚĂŐĞĚƌŽƉͿŝŶƐƵƉƉůLJĐŝƌĐƵŝƚ͘