Troubleshooting, cont’d.
Possible Cause:
■
Bad capillary tube position
■
Faulty thermostat
■
Faulty control module
Troubleshooting - Test G, Refrigerator Gets Too Cold
Is the capillar
y
tube full
y
inserted into
the pocket in the evaporator plate?
START
test unit.
Yes
No
Disconnect wires fro
m
the ther
m
o-
stat. Did the unit stop running?
Replace the ther
m
ostat, test unit.
No
Leave DC suppl
y
connected and
re
m
ove unit fro
m
its enclosure.
Disconnect ther
m
ostat wires at the
control
m
odule ter
m
inals C and T.
Did the unit stop running?
Replace power control
m
odule,
test unit.
No
Yes
Repair the shorted wires between
the ther
m
ostat and the control
m
odule, test unit.
Perfor
m
Diagnostic Prechecks.
Yes
NOR000726g-7a