9
inches apart to avoid cross-talk. Call NORAC Systems and describe your
situation to get pricing for an additional sensor, cabling, and mounting
brackets/hardware.
Once you have your sensor in place and electrically connected, carry out the
following steps via the control panel to configure your system for four-sensor
operation.
1.
Make sure you are in manual mode, at the operating screen.
↓↓↓↓
35 MM 35
35 MM 35
35 MM 35
35 MM 35
2.
Navigate to the "More ?" item in the SENSOR DISPLAY menu. Press
AUTO (YES).
3.
Navigate to the "Main ?" item in the SENSOR DISPLAY menu. Press
AUTO (YES).
4.
At the "ML" prompt, it will likely show the following:
↓↓↓↓
ML proxy
ML proxy
ML proxy
ML proxy
Toggle the “+” switch to search for sensors. Then use the “+” switch to
scroll through the list of sensor serial numbers. When the serial number
(that matches the new main sensor that you have installed) is shown,
press AUTO (YES) to confirm. Toggle SENSOR DISPLAY once to
display the “MLht” menu item to check/calibrate the new sensor’s height.
5.
Press and hold SETUP for two seconds to return to the operational
screen.
NOTE: Configuring the additional sensor may also be accomplished by
performing a “Install”, as described in Section 6.2.
4.4 Power Cable
The power cable supplies 12 volt D.C. negative ground power to the
control panel and the sensors. The system will function properly with a
supply between 11 and 28 volts and may draw up to 10 amperes during
normal operation.
The control panel contains intelligent valve drive circuitry that helps to
protect the system against short circuits and other wiring problems.
However, it is still recommended to connect the UC4 power cable to a
fused supply, that turns on and off with the ignition key of the
sprayer/tractor.